Literature DB >> 32205896

Improving EEG Muscle Artifact Removal With an EMG Array.

Juan Andrés Mucarquer1, Pavel Prado2, María-José Escobar1, Wael El-Deredy3, Matías Zañartu1.   

Abstract

Removal of artifacts induced by muscle activity is crucial for analysis of the electroencephalogram (EEG), and continues to be a challenge in experiments where the subject may speak, change facial expressions, or move. Ensemble empirical mode decomposition with canonical correlation analysis (EEMD-CCA) has been proven to be an efficient method for denoising of EEG contaminated with muscle artifacts. EEMD-CCA, likewise the majority of algorithms, does not incorporate any statistical information of the artifact, namely, electromyogram (EMG) recorded over the muscles actively contaminating the EEG. In this paper, we propose to extend EEMD-CCA in order to include an EMG array as information to aid the removal of artifacts, assessing the performance gain achieved when the number of EMG channels grow. By filtering adaptively (recursive least squares, EMG array as reference) each component resulting from CCA, we aim to ameliorate the distortion of brain signals induced by artifacts and denoising methods. We simulated several noise scenarios based on a linear contamination model, between real and synthetic EEG and EMG signals, and varied the number of EMG channels available to the filter. Our results exhibit a substantial improvement in the performance as the number of EMG electrodes increase from 2 to 16. Further increasing the number of EMG channels up to 128 did not have a significant impact on the performance. We conclude by recommending the use of EMG electrodes to filter components, as it is a computationally inexpensive enhancement that impacts significantly on performance using only a few electrodes.

Entities:  

Keywords:  Adaptive filtering; artifact removal; blind-source-separation; electroencephalogram (EEG); electromyogram (EMG); muscle artifacts

Year:  2019        PMID: 32205896      PMCID: PMC7088455          DOI: 10.1109/tim.2019.2906967

Source DB:  PubMed          Journal:  IEEE Trans Instrum Meas        ISSN: 0018-9456            Impact factor:   4.016


  19 in total

1.  Independent component analysis: algorithms and applications.

Authors:  A Hyvärinen; E Oja
Journal:  Neural Netw       Date:  2000 May-Jun

2.  ICA-based muscle artefact correction of EEG data: what is muscle and what is brain? Comment on McMenamin et al.

Authors:  Sebastian Olbrich; Johannes Jödicke; Christian Sander; Hubertus Himmerich; Ulrich Hegerl
Journal:  Neuroimage       Date:  2010-05-02       Impact factor: 6.556

3.  Source separation from single-channel recordings by combining empirical-mode decomposition and independent component analysis.

Authors:  Bogdan Mijović; Maarten De Vos; Ivan Gligorijević; Joachim Taelman; Sabine Van Huffel
Journal:  IEEE Trans Biomed Eng       Date:  2010-06-10       Impact factor: 4.538

4.  When EMG contamination does not necessarily hide high-frequency EEG: scalp electrical recordings before and after Dysport injections.

Authors:  Julia A Boytsova; Sergey G Danko; Svyatoslav V Medvedev
Journal:  Exp Brain Res       Date:  2016-06-27       Impact factor: 1.972

5.  Electromyogenic Artifacts and Electroencephalographic Inferences Revisited.

Authors:  Brenton W McMenamin; Alexander J Shackman; Lawrence L Greischar; Richard J Davidson
Journal:  Neuroimage       Date:  2010-08-02       Impact factor: 6.556

6.  Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG.

Authors:  Brenton W McMenamin; Alexander J Shackman; Jeffrey S Maxwell; David R W Bachhuber; Adam M Koppenhaver; Lawrence L Greischar; Richard J Davidson
Journal:  Neuroimage       Date:  2009-10-13       Impact factor: 6.556

Review 7.  Electromyogenic artifacts and electroencephalographic inferences.

Authors:  Alexander J Shackman; Brenton W McMenamin; Heleen A Slagter; Jeffrey S Maxwell; Lawrence L Greischar; Richard J Davidson
Journal:  Brain Topogr       Date:  2009-02-12       Impact factor: 3.020

8.  FieldTrip: Open source software for advanced analysis of MEG, EEG, and invasive electrophysiological data.

Authors:  Robert Oostenveld; Pascal Fries; Eric Maris; Jan-Mathijs Schoffelen
Journal:  Comput Intell Neurosci       Date:  2010-12-23

9.  Beware: Recruitment of Muscle Activity by the EEG-Neurofeedback Trainings of High Frequencies.

Authors:  Katarzyna Paluch; Katarzyna Jurewicz; Jacek Rogala; Rafał Krauz; Marta Szczypińska; Mirosław Mikicin; Andrzej Wróbel; Ewa Kublik
Journal:  Front Hum Neurosci       Date:  2017-03-20       Impact factor: 3.169

10.  Hybrid ICA-Regression: Automatic Identification and Removal of Ocular Artifacts from Electroencephalographic Signals.

Authors:  Malik M Naeem Mannan; Myung Y Jeong; Muhammad A Kamran
Journal:  Front Hum Neurosci       Date:  2016-05-03       Impact factor: 3.169

View more
  5 in total

1.  Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)-A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG.

Authors:  Yongcheng Li; Po T Wang; Mukta P Vaidya; Robert D Flint; Charles Y Liu; Marc W Slutzky; An H Do
Journal:  Front Neurosci       Date:  2021-01-15       Impact factor: 4.677

2.  Refinement of High-Gamma EEG Features From TBI Patients With Hemicraniectomy Using an ICA Informed by Simulated Myoelectric Artifacts.

Authors:  Yongcheng Li; Po T Wang; Mukta P Vaidya; Robert D Flint; Charles Y Liu; Marc W Slutzky; An H Do
Journal:  Front Neurosci       Date:  2020-11-24       Impact factor: 4.677

3.  Single channel approach for filtering electroencephalographic signals strongly contaminated with facial electromyography.

Authors:  Carlos Magno Medeiros Queiroz; Gustavo Moreira da Silva; Steffen Walter; Luciano Brinck Peres; Luiza Maire David Luiz; Samila Carolina Costa; Kelly Christina de Faria; Adriano Alves Pereira; Marcus Fraga Vieira; Ariana Moura Cabral; Adriano de Oliveira Andrade
Journal:  Front Comput Neurosci       Date:  2022-07-26       Impact factor: 3.387

4.  Characterizing and Removing Artifacts Using Dual-Layer EEG during Table Tennis.

Authors:  Amanda Studnicki; Ryan J Downey; Daniel P Ferris
Journal:  Sensors (Basel)       Date:  2022-08-05       Impact factor: 3.847

5.  Eye-blink artifact removal from single channel EEG with k-means and SSA.

Authors:  Ajay Kumar Maddirala; Kalyana C Veluvolu
Journal:  Sci Rep       Date:  2021-05-26       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.