Literature DB >> 32199832

A low-cost paper-based aptasensor for simultaneous trace-level monitoring of mercury (II) and silver (I) ions.

Zahra Khoshbin1, Mohammad Reza Housaindokht2, Asma Verdian3.   

Abstract

Mercury (Hg2+) and silver (Ag+) ions possess the harmful effects on public health and environment that makes it essential to develop the sensing techniques with great sensitivity for the ions. Metal ions commonly coexist in the different biological and environmental systems. Hence, it is an urgent demand to design a simple method for the simultaneous detection of metal ions, peculiarly in the case of coexisting Hg2+ and Ag+. This study introduces a low-cost paper-based aptasensor to monitor Hg2+ and Ag+, simultaneously. The strategy of the sensing array is according to the conformational changes of Hg2+- and Ag+-specific aptamers and their release from the GO surface after the injection of the target sample on the sensing platform. Through monitoring the fluorescence recovery changes against the concentrations of the ions, Hg2+ and Ag+ can be determined as low as 1.33 and 1.01 pM. The paper-based aptasensor can simultaneously detect the ions within about 10 min. The aptasensor is applied prosperously to monitor Hg2+ and Ag+ in human serum, water, and milk. The designed aptasensor with the main advantages of simplicity and feasibility holds the supreme potential to develop a cost-effective sensing method for environmental monitoring, food control, and human diagnostics.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aptamer; FRET; Graphene oxide; Hairpin structure; Paper-based aptasensor; Simultaneous detection

Mesh:

Substances:

Year:  2020        PMID: 32199832     DOI: 10.1016/j.ab.2020.113689

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  4 in total

Review 1.  Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review.

Authors:  Wei-Chun Tai; Yu-Chi Chang; Dean Chou; Lung-Ming Fu
Journal:  Biosensors (Basel)       Date:  2021-08-03

2.  Heavy Metal Ions Trigger a Fluorescent Quenching in DNA-Organic Semiconductor Hybrid Assemblies.

Authors:  Xianyang Li; Yuhui Feng; Tao Yi; Yan Piao; Dong Hyuk Park; Longzhen Cui; Chunzhi Cui
Journal:  Polymers (Basel)       Date:  2022-08-31       Impact factor: 4.967

Review 3.  Advances in aptamer screening and aptasensors' detection of heavy metal ions.

Authors:  Wenfei Guo; Chuanxiang Zhang; Tingting Ma; Xueying Liu; Zhu Chen; Song Li; Yan Deng
Journal:  J Nanobiotechnology       Date:  2021-06-01       Impact factor: 10.435

Review 4.  Recent Advances in Microfluidic Devices for Contamination Detection and Quality Inspection of Milk.

Authors:  Hwee-Yeong Ng; Wen-Chin Lee; Chia-Te Kung; Lung-Chih Li; Chien-Te Lee; Lung-Ming Fu
Journal:  Micromachines (Basel)       Date:  2021-05-14       Impact factor: 2.891

  4 in total