Literature DB >> 32199329

Measurement of total and unbound bictegravir concentrations in plasma and cerebrospinal fluid by UHPLC-MS/MS.

Raúl Rigo-Bonnin1, Juan Manuel Tiraboschi2, Marta Álvarez-Álvarez3, Gloria Ainara Pérez-Fernández3, Mercedes Sanjuás-Iglesias3, Sofía Scévola2, Jordi Niubó4, Sebastián Videla5, Daniel Podzamczer2.   

Abstract

Bictegravir is a novel integrase strand transfer inhibitor, administrated in co-formulation with tenofovir alafenamide and emtricitabine (Biktarvy®), indicated in the management of HIV-1 infection in patients not previously treated with antiretroviral therapy. Bictegravir is highly bound to plasma proteins, and this significantly determines its clearance, solubility, and activity. These characteristics are crucial determinants of bictegravir penetration into human body compartments, as the central nervous system. We developed and validated UHPLC-MS/MS procedures to measure total and unbound bictegravir concentrations in plasma and cerebrospinal fluid. Simple protein precipitation with acetonitrile was implemented to prepare plasma and cerebrospinal fluid samples. Sample preparation was preceded by ultrafiltration for measuring unbound bictegravir concentrations. Chromatographic separations were achieved on an Acquity® UHPLC® BEHTM (2.1 × 100 mm id, 1.7 μm) reverse-phase C18 column using an isocratic mobile phase 20:80 (v/v) water/acetonitrile with 0.1% formic. Bictegravir and its internal standard (bictegravir-15N d2) were detected by electrospray ionization mass spectrometry in positive and multiple reaction monitoring modes, using transitions of 450.2→289.2/145.4 and 453.2→289.2, respectively. Ultrafiltration procedures presented non-specific bindings of (8.6 ± 1.2) % for bictegravir in plasma and (26.6 ± 3.1) % for bictegravir in cerebrospinal fluid. Linearity was observed between (10.70-8560) μg/L, (1.07-856.0) μg/L for total and unbound bictegravir in plasma, and 0.107-26.75 μg/L for total and unbound bictegravir in cerebrospinal fluid. Imprecisions, absolute relative biases, normalized-matrix factors, and normalized-recoveries were ≤14.4%, ≤13.8%, (97.4-102.5) %, and (99.8-105.1) %, respectively. No significant interferences and carry-over were observed. The validated UHPLC-MS/MS procedures could be useful for pharmacokinetic and pharmacodynamic studies.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cerebrospinal fluid; UHPLC-MS/MS; plasma; total bictegravir; ultrafiltration; unbound bictegravir

Mesh:

Substances:

Year:  2020        PMID: 32199329     DOI: 10.1016/j.jpba.2020.113250

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

Review 1.  Tandem mass spectrometry of small-molecule antiviral drugs: 1. HIV-related antivirals.

Authors:  W M A Niessen
Journal:  Int J Mass Spectrom       Date:  2020-06-15       Impact factor: 1.986

2.  Acute HIV infection with presentations mimicking acalculous cholecystitis: A case report.

Authors:  Wang-Da Liu; Chih-Ning Cheng; Ya-Ting Lin; Ching-Hua Kuo; Shu-Yuan Ho; Chien-Ching Hung
Journal:  Medicine (Baltimore)       Date:  2021-07-16       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.