Literature DB >> 32197920

A novel parameter for the prediction of pedicle screw fixation in cancellous bone - A biomechanical study on synthetic foam.

Martin Weidling1, Christoph Oefner2, Stephan Schoenfelder3, Christoph-E Heyde4.   

Abstract

Pedicle screw loosening is still observed in clinical practice. Therefore, the understanding of the interaction between screw and bone is evermore subject of research. However, complex relationships between screw design and anchorage are rarely examined. For this reason, it is investigated whether screw fixation is predictable by a parameter that maps the thread. Two types of pedicle screws, 6.5 mm and 7.5 mm in major diameter, respectively, are pulled out from synthetic polyurethane foam. Representative design parameters were evaluated with regard to their influence on the insertion torque and pull-out strength. A correlation between the insertion torque and the degree of compacting of the bone was observed. In addition, the pull-out strength was found to be related to the contact area of the bone-screw interface, the bone volume displaced during screwing, and the displaced diameter. The relationship between insertion torque and pull-out strength was also linear. In addition, a relational equation was derived for the pull-out strength versus the insertion torque with the major diameter as scaling factor. Thus, the pull-out strength from cancellous bone is predictable by a representative design parameter. Furthermore, the derived relation equation opens a new perspective for the evaluation of screw fixation.
Copyright © 2020. Published by Elsevier Ltd.

Entities:  

Keywords:  Bone compacting; Bone compression; Contact area of bone-screw-interface; Insertion torque; Pedicle screw; Polyurethane foam; Pull-out strength

Mesh:

Substances:

Year:  2020        PMID: 32197920     DOI: 10.1016/j.medengphy.2020.03.001

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Deterioration of the fixation segment's stress distribution and the strength reduction of screw holding position together cause screw loosening in ALSR fixed OLIF patients with poor BMD.

Authors:  Jing-Chi Li; Zhi-Qiang Yang; Tian-Hang Xie; Zhe-Tao Song; Yue-Ming Song; Jian-Cheng Zeng
Journal:  Front Bioeng Biotechnol       Date:  2022-08-30

2.  The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically.

Authors:  Jing-Chi Li; Tian-Hang Xie; Zhuang Zhang; Zhe-Tao Song; Yue-Ming Song; Jian-Cheng Zeng
Journal:  Front Bioeng Biotechnol       Date:  2022-04-08

3.  Influence of thread design on anchorage of pedicle screws in cancellous bone: an experimental and analytical analysis.

Authors:  Martin Weidling; Martin Heilemann; Stephan Schoenfelder; Christoph E Heyde
Journal:  Sci Rep       Date:  2022-05-16       Impact factor: 4.996