Literature DB >> 32197257

Thoracic electrical impedance tomography in Chinese hospitals: a review of clinical research and daily applications.

Zhanqi Zhao1, Feng Fu, Inéz Frerichs.   

Abstract

Chinese scientists and researchers have a long history with electrical impedance tomography (EIT), which can be dated back to the 1980s. No commercial EIT devices for chest imaging were available until the year 2014 when the first device received its approval from the China Food and Drug Administration. Ever since then, clinical research and daily applications have taken place in Chinese hospitals. Up to this date (2019.11) 47 hospitals have been equipped with 50 EIT devices. Twenty-three SCI publications are recorded and a further 21 clinical trials are registered. Thoracic EIT is mainly used in patients before or after surgery, or in intensive care units (ICU). Application fields include the development of strategies for protective lung ventilation (e.g. tidal volume and positive end-expiratory pressure (PEEP) titration, recruitment, choice of ventilation mode and weaning from ventilator), regional lung perfusion monitoring, perioperative monitoring, and potential feedback for rehabilitation. The main challenges for promoting clinical use of EIT are the financial cost and the education of personnel. In this review, the past, present and future of EIT in China are introduced and discussed.

Entities:  

Mesh:

Year:  2020        PMID: 32197257     DOI: 10.1088/1361-6579/ab81df

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  11 in total

1.  Monitoring postoperative lung recovery using electrical impedance tomography in post anesthesia care unit: an observational study.

Authors:  Nadine Hochhausen; Torsten Kapell; Martin Dürbaum; Andreas Follmann; Rolf Rossaint; Michael Czaplik
Journal:  J Clin Monit Comput       Date:  2021-09-20       Impact factor: 1.977

2.  COVID-19 pneumonia: phenotype assessment requires bedside tools.

Authors:  Zhanqi Zhao; Wan-Hsuan Kung; Hou-Tai Chang; Yeong-Long Hsu; Inéz Frerichs
Journal:  Crit Care       Date:  2020-05-29       Impact factor: 9.097

Review 3.  A narrative review of electrical impedance tomography in lung diseases with flow limitation and hyperinflation: methodologies and applications.

Authors:  Ling Sang; Zhanqi Zhao; Zhimin Lin; Xiaoqing Liu; Nanshan Zhong; Yimin Li
Journal:  Ann Transl Med       Date:  2020-12

4.  Spatial Ventilation Inhomogeneity Determined by Electrical Impedance Tomography in Patients With Chronic Obstructive Lung Disease.

Authors:  Inéz Frerichs; Livia Lasarow; Claas Strodthoff; Barbara Vogt; Zhanqi Zhao; Norbert Weiler
Journal:  Front Physiol       Date:  2021-12-13       Impact factor: 4.566

5.  Emerging Trends and Hot Spots of Electrical Impedance Tomography Applications in Clinical Lung Monitoring.

Authors:  Zhe Li; Shaojie Qin; Chen Chen; Shuya Mei; Yulong Yao; Zhanqi Zhao; Wen Li; Yuxiao Deng; Yuan Gao
Journal:  Front Med (Lausanne)       Date:  2022-01-31

6.  Influence of overdistension/recruitment induced by high positive end-expiratory pressure on ventilation-perfusion matching assessed by electrical impedance tomography with saline bolus.

Authors:  Huaiwu He; Yi Chi; Yun Long; Siyi Yuan; Inéz Frerichs; Knut Möller; Feng Fu; Zhanqi Zhao
Journal:  Crit Care       Date:  2020-09-29       Impact factor: 9.097

7.  Regional ventilation distribution in healthy lungs: can reference values be established for electrical impedance tomography parameters?

Authors:  Lin Yang; Meng Dai; Xinsheng Cao; Knut Möller; Mantas Dargvainis; Inéz Frerichs; Tobias Becher; Feng Fu; Zhanqi Zhao
Journal:  Ann Transl Med       Date:  2021-05

8.  Editorial: CardioPulmonary Physiology: Novel Approaches to Pulmonary Function and Critical Care.

Authors:  Zhanqi Zhao; Ling Sang; Tong In Oh
Journal:  Front Physiol       Date:  2022-01-03       Impact factor: 4.566

9.  Electrical Impedance Tomography - Recent Applications and Developments.

Authors:  Sofiene Mansouri; Yousef Alharbi; Fatma Haddad; Souhir Chabcoub; Anwar Alshrouf; Amr A Abd-Elghany
Journal:  J Electr Bioimpedance       Date:  2021-11-20

10.  System introduction and evaluation of the first Chinese chest EIT device for ICU applications.

Authors:  Shuo-Yao Qu; Meng Dai; Shuo Wu; Zhi-Rang Lv; Xin-Yu Ti; Feng Fu
Journal:  Sci Rep       Date:  2021-09-29       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.