Mikaël Simard1, Arthur Lalonde1, Hugo Bouchard2.
Abstract
The purpose of this work is, firstly, to propose an optimized parametrization of the attenuation coefficient to describe human tissues in the context of projection-based material characterization with multi-energy CT. The approach is based on eigentissue decomposition (ETD). Secondly, to evaluate its benefits in terms of accuracy and precision of radiotherapy-related parameters against established parametrizations. The attenuation coefficient is parametrized as a linear combination of virtual materials, eigentissues, obtained by performing principal component analysis on a set of reference tissues in order to optimally represent human tissue composition. Two implementations of ETD are compared with other pre-reconstruction formalisms established for dual-energy and photon-counting CT in a simulation framework. The first implementation uses a single set of eigentissues to describe all human tissues, while the second uses different sets of eigentissues to characterize soft tissues and bones, and includes a post-reconstruction classification step. The simulation framework evaluates the reconstruction accuracy of various radiotherapy-related quantities over a range of 71 human tissues for various noise levels. Compared to conventional parametrizations, the first implementation of ETD reduces the mean error and root-mean-square error (RMSE) in two radiotherapy-related quantities (the proton stopping power and the mass energy absorption coefficient of 21 keV photons from 103Pd seeds used in brachytherapy) for all noise levels and modalities investigated. This illustrates that a decomposition basis selected with principal component analysis is superior to an arbitrary pair of materials to describe human tissues. The mean error on radiotherapy-related parameters can be further reduced with the classification-based approach. In the context of pre-reconstruction material characterization with multi-energy CT, parametrizing the attenuation coefficient with eigentissues provides a more accurate and precise evaluation of human tissues properties for radiotherapy. Accurate quantification can thus be achieved without the need to parametrize tissues using unphysical parameters, such as the energy-dependent effective atomic number.Entities:
Keywords: dual-energy computed tomography; multi-energy computed tomography; parametrization; projection-based; tissue characterization
Year: 2020 PMID: 32187579 DOI: 10.1088/1361-6560/ab8107
Source DB: PubMed Journal: Phys Med Biol ISSN: 0031-9155 Impact factor: 3.609