Literature DB >> 32178322

Simultaneous Measurement of Tricarboxylic Acid Cycle Intermediates in Different Biological Matrices Using Liquid Chromatography-Tandem Mass Spectrometry; Quantitation and Comparison of TCA Cycle Intermediates in Human Serum, Plasma, Kasumi-1 Cell and Murine Liver Tissue.

Ramji Rathod1, Bharat Gajera1, Kenneth Nazir1, Janne Wallenius1,2, Vidya Velagapudi1.   

Abstract

The tricarboxylic acid (TCA) cycle is a central part of carbon and energy metabolism, also connecting to glycolysis, amino acid, and lipid metabolism. The quantitation of the TCA cycle intermediate within one method is lucrative due to the interest in central carbon metabolism profiling in cells and tissues. In addition, TCA cycle intermediates in serum have been discovered to correspond as biomarkers to various underlying pathological conditions. In this work, an Liquid Chromatography-Mass Spectrometry/Mass Spectrometry-based quantification method is developed and validated, which takes advantage of fast, specific, sensitive, and cost-efficient precipitation extraction. Chromatographic separation is achieved while using Atlantis dC18 2.1 mm × 100 mm, particle size 3-μm of Waters column with a gradient elution mobile phase while using formic acid in water (0.1% v/v) and acetonitrile. Linearity was clearly seen over a calibration range of: 6.25 to 6400 ng/mL (r2 > 0.980) for malic acid; 11.72 to 12,000 ng/mL (r2 > 0.980) for cis-aconitic acid and L-aspartic acid; 29.30 to 30,000 ng/mL (r2 > 0.980) for isocitric acid, l-serine, and l-glutamic acid; 122.07 to 125,000 ng/mL (r2 > 0.980) for citric acid, glycine, oxo-glutaric acid, l-alanine, and l-glutamine; 527.34 to 540,000 ng/mL (r2 > 0.980) for l-lactic acid; 976.56 to 1,000,000 ng/mL (r2 > 0.980) for d-glucose; 23.44 to 24,000 ng/mL (r2 > 0.980) for fumaric acid and succinic acid; and, 244.14 to 250,000 ng/mL (r2 > 0.980) for pyruvic acid. Validation was carried out, as per European Medicines Agency (EMA) "guidelines on bioanalytical method validation", for linearity, precision, accuracy, limit of detection (LOD), limit of quantification (LLOQ), recovery, matrix effect, and stability. The recoveries from serum and tissue were 79-119% and 77-223%, respectively. Using this method, we measured TCA intermediates in serum, plasma (NIST 1950 SRM), and in mouse liver samples. The concentration found in NIST SRM 1950 (n = 6) of glycine (246.4 µmol/L), l-alanine (302.4 µmol/L), and serine (92.9 µmol/L).

Entities:  

Keywords:  bioanalytical method validation; chromatography; mass spectrometry; metabolites; tricarboxylic acid (TCA) cycle

Year:  2020        PMID: 32178322     DOI: 10.3390/metabo10030103

Source DB:  PubMed          Journal:  Metabolites        ISSN: 2218-1989


  3 in total

1.  High-throughput nuclear magnetic resonance measurement of citrate in serum and plasma in the clinical laboratory.

Authors:  Erwin Garcia; Margery A Connelly; Steven P Matyus; James D Otvos; Irina Shalaurova
Journal:  Pract Lab Med       Date:  2021-03-18

Review 2.  Reference materials for MS-based untargeted metabolomics and lipidomics: a review by the metabolomics quality assurance and quality control consortium (mQACC).

Authors:  Katrice A Lippa; Juan J Aristizabal-Henao; Richard D Beger; John A Bowden; Corey Broeckling; Chris Beecher; W Clay Davis; Warwick B Dunn; Roberto Flores; Royston Goodacre; Gonçalo J Gouveia; Amy C Harms; Thomas Hartung; Christina M Jones; Matthew R Lewis; Ioanna Ntai; Andrew J Percy; Dan Raftery; Tracey B Schock; Jinchun Sun; Georgios Theodoridis; Fariba Tayyari; Federico Torta; Candice Z Ulmer; Ian Wilson; Baljit K Ubhi
Journal:  Metabolomics       Date:  2022-04-09       Impact factor: 4.747

3.  Gut microbiota-mediated tributyltin-induced metabolic disorder in rats.

Authors:  Ge-Hui Yuan; Zhan Zhang; Xing-Su Gao; Jun Zhu; Wen-Hui Guo; Li Wang; Ping Ding; Ping Jiang; Lei Li
Journal:  RSC Adv       Date:  2020-12-08       Impact factor: 4.036

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.