Literature DB >> 32175391

Effects of collimated and focused low-intensity pulsed ultrasound stimulation on the mandible repair in rabbits.

Xiaohan Liu1, Ying Hu2, Lin Wu1, Shujun Li3.   

Abstract

BACKGROUND: This study was to evaluate the effects of low-intensity collimated pulse ultrasound (LICU) and low-intensity focused-pulse ultrasound (LIFU) stimulation on the osteogenesis in the porous silicon carbide (SiC) scaffold implanted in the rabbit mandible.
METHODS: Rabbits were randomly divided into LIFU group, LICU group and control group (without ultrasound treatment). The intensities of LICU and LIFU were 30 and 300 mW/cm2, respectively. The subcutaneous and subperiosteal temperatures were measured continuously during the 20-min ultrasound treatment. Then, the porous SiC scaffolds were implanted into the mandible, followed by LICU or LIFU once daily, and the quantity and structure of bone were assessed by methylene blue-acid fuchsin staining and micro-CT at 3, 6 and 9 weeks after implantation.
RESULTS: The changes in the subcutaneous and subperiosteal temperatures during LICU and LIFU were less than 1 °C. The bone mass increased and the structure of bone tissues became more mature over time. The bone mass and mean pore occupancy fraction (POF) in the LIFU group were significantly greater than in the LICU group at three time points (P<0.05). Bone ingrowth in different directions was observed, and the new bone formation in the mesial, distal, top, and lingual sides of the implants in the LIFU group was greater than in the LICU group and control group (P<0.05).
CONCLUSIONS: LIFU and LICU may effectively promote bone formation in the mandible scaffold, and LIFU significantly accelerates bone formation in both buccal side and lingual side of the scaffold. 2020 Annals of Translational Medicine. All rights reserved.

Entities:  

Keywords:  Osteogenesis; low-intensity collimated pulse ultrasound (LICU); low-intensity focused-pulse ultrasound (LIFU); porous SiC scaffold

Year:  2020        PMID: 32175391      PMCID: PMC7049032          DOI: 10.21037/atm.2019.12.89

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


  19 in total

1.  Study of thermal effects of ultrasound stimulation on fracture healing.

Authors:  Walter Hong-Shong Chang; Jui-Sheng Sun; Su-Pei Chang; James C Lin
Journal:  Bioelectromagnetics       Date:  2002-05       Impact factor: 2.010

2.  Interaction between parallel polymer fibers insonificated by ultrasound of low/mild intensity: an analytical theory and experiments.

Authors:  Junru Wu; Di Chen; Helene M Langevin; Wesley L Nyborg
Journal:  Ultrasonics       Date:  2011-10-31       Impact factor: 2.890

3.  Low-intensity pulsed ultrasound accelerates periodontal wound healing after flap surgery.

Authors:  H Ikai; T Tamura; T Watanabe; M Itou; A Sugaya; S Iwabuchi; Y Mikuni-Takagaki; S Deguchi
Journal:  J Periodontal Res       Date:  2008-04       Impact factor: 4.419

Review 4.  Noninvasive Focused Ultrasound for Neuromodulation: A Review.

Authors:  Paul Bowary; Benjamin D Greenberg
Journal:  Psychiatr Clin North Am       Date:  2018-07-17

5.  Noninvasive, targeted gene therapy for acute spinal cord injury using LIFU-mediated BDNF-loaded cationic nanobubble destruction.

Authors:  Zhaojun Song; Yongjie Ye; Zhi Zhang; Jieliang Shen; Zhenming Hu; Zhigang Wang; Jiazhuang Zheng
Journal:  Biochem Biophys Res Commun       Date:  2018-01-31       Impact factor: 3.575

6.  Accelerated healing of distal radial fractures with the use of specific, low-intensity ultrasound. A multicenter, prospective, randomized, double-blind, placebo-controlled study.

Authors:  T K Kristiansen; J P Ryaby; J McCabe; J J Frey; L R Roe
Journal:  J Bone Joint Surg Am       Date:  1997-07       Impact factor: 5.284

7.  Effect of low-intensity pulsed ultrasound on the biological behavior of osteoblasts on porous titanium alloy scaffolds: An in vitro and in vivo study.

Authors:  Hongjuan Cao; Lifang Feng; Zhenxian Wu; Wentao Hou; Shujun Li; Yulin Hao; Lin Wu
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-05-19       Impact factor: 7.328

8.  Enhancement of cell ingrowth, proliferation, and early differentiation in a three-dimensional silicon carbide scaffold using low-intensity pulsed ultrasound.

Authors:  Lin Wu; Liangjun Lin; Yi-Xian Qin
Journal:  Tissue Eng Part A       Date:  2014-07-24       Impact factor: 3.845

9.  Acceleration of Bone Defect Healing and Regeneration by Low-Intensity Ultrasound Radiation Force in a Rat Tibial Model.

Authors:  Jingbo Liu; Xiaofei Li; Dongye Zhang; Jian Jiao; Lin Wu; Fengyu Hao; Yi-Xian Qin
Journal:  Ultrasound Med Biol       Date:  2018-10-01       Impact factor: 2.998

10.  Low-intensity pulsed ultrasound induces cartilage matrix synthesis and reduced MMP13 expression in chondrocytes.

Authors:  Jumpei Sekino; Mayu Nagao; Shunichiro Kato; Mayu Sakai; Kimiko Abe; Enri Nakayama; Mitsuyasu Sato; Yuki Nagashima; Haruka Hino; Natsuko Tanabe; Takayuki Kawato; Masao Maeno; Naoto Suzuki; Koichiro Ueda
Journal:  Biochem Biophys Res Commun       Date:  2018-10-19       Impact factor: 3.575

View more
  1 in total

Review 1.  From the Matrix to the Nucleus and Back: Mechanobiology in the Light of Health, Pathologies, and Regeneration of Oral Periodontal Tissues.

Authors:  Martin Philipp Dieterle; Ayman Husari; Thorsten Steinberg; Xiaoling Wang; Imke Ramminger; Pascal Tomakidi
Journal:  Biomolecules       Date:  2021-05-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.