Literature DB >> 32174323

Designing 3D prosthetic templates for maxillofacial defect rehabilitation: A comparative analysis of different virtual workflows.

Taseef Hasan Farook1, Nafij Bin Jamayet2, Johari Yap Abdullah3, Jawaad Ahmed Asif4, Zainul Ahmad Rajion5, Mohammad Khursheed Alam6.   

Abstract

OBJECTIVE: To design and compare the outcome of commercial (CS) and open source (OS) software-based 3D prosthetic templates for rehabilitation of maxillofacial defects using a low powered personal computer setup.
METHOD: Medical image data for five types of defects were selected, segmented, converted and decimated to 3D polygon models on a personal computer. The models were transferred to a computer aided design (CAD) software which aided in designing the prosthesis according to the virtual models. Two templates were designed for each defect, one by an OS (free) system and one by CS. The parameters for analyses were the virtual volume, Dice similarity coefficient (DSC) and Hausdorff's distance (HD) and were executed by the OS point cloud comparison tool. RESULT: There was no significant difference (p > 0.05) between CS and OS when comparing the volume of the template outputs. While HD was within 0.05-4.33 mm, evaluation of the percentage similarity and spatial overlap following the DSC showed an average similarity of 67.7% between the two groups. The highest similarity was with orbito-facial prostheses (88.5%) and the lowest with facial plate prosthetics (28.7%).
CONCLUSION: Although CS and OS pipelines are capable of producing templates which are aesthetically and volumetrically similar, there are slight comparative discrepancies in the landmark position and spatial overlap. This is dependent on the software, associated commands and experienced decision-making. CAD-based templates can be planned on current personal computers following appropriate decimation.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Auricle; Digital pipeline; Facial defect; Maxillofacial prosthetics; Nasal; Obturator; Open source; Orbital; Similarity coefficient

Mesh:

Year:  2020        PMID: 32174323     DOI: 10.1016/j.compbiomed.2020.103646

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  2 in total

1.  Color variations during digital imaging of facial prostheses subjected to unfiltered ambient light and image calibration techniques within dental clinics: An in vitro analysis.

Authors:  Farah Rashid; Nafij Bin Jamayet; Taseef Hasan Farook; Matheel Al-Rawas; Aparna Barman; Yanti Johari; Tahir Yusuf Noorani; Johari Yap Abdullah; Sumaiya Zabin Eusufzai; Mohammad Khursheed Alam
Journal:  PLoS One       Date:  2022-08-29       Impact factor: 3.752

Review 2.  Rapid Prototyping in Maxillofacial Rehabilitation: A Review of Literature.

Authors:  Akansha V Bansod; Sweta G Pisulkar; Chinmayee Dahihandekar; Arushi Beri
Journal:  Cureus       Date:  2022-09-09
  2 in total