Cyclic fatigue resistance and energy dispersive X-ray spectroscopy analysis of novel heat-treated nickel-titanium instruments at body temperature.

Seniha Micoogullari Kurt1, Mehmet Emin Kaval1, Burcu Serefoglu1, Gözde Kandemir Demirci1, Mehmet Kemal Çalışkan1.   

Abstract

The aim of this study was to evaluate the cyclic fatigue resistance of Dia-X, WaveOne Gold and One Curve files in a water bath at intracanal temperature (35°C). Thirty-nine instruments Dia-X, WaveOne Gold, and One Curve systems (n = 13) were tested in an artificial canal with a curvature angle of 60° and a radius of 3 mm. A water bath setup at a temperature of 35°C was used to simulate the intracanal temperature and time to fracture (TTF) as seconds was recorded. The mean data were analyzed statistically using one-way ANOVA, and post hoc Tukey test (p = .05). The fractured surface of the instruments was examined with scanning electron microscopy (SEM) and chemical composition of the instruments were investigated with energy dispersive X-ray spectroscopy (EDS). Statistically significant differences were detected in TTF values of all the systems as follows: One Curve > WaveOne Gold > Dia-X (p < .05). One Curve instruments demonstrated the highest TTF values in all the tested instruments. The EDS microanalysis revealed similar NiTi composition of on the surface of One Curve, WaveOne Gold, and Dia-X instruments. The novel manufacturing process, including C-wire heat treatment and the variable cross-section of the One Curve files, could be the main factors affecting the fatigue life of the instruments.
© 2020 Wiley Periodicals, Inc.

Entities:  

Keywords:  EDS analysis; NiTi; cyclic fatigue resistance; heat treatment

Year:  2020        PMID: 32170795     DOI: 10.1002/jemt.23469

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  3 in total

1.  Ex-Vivo Comparison of Torsional Stress on Nickel-Titanium Instruments Activated by Continuous Rotation or Adaptive Motion.

Authors:  Joo Yeong Lee; Sang Won Kwak; Jung-Hong Ha; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

2.  Evaluation of the Cyclic Fatigue of Two Single Files at Body and Room Temperature with Different Radii of Curvature.

Authors:  Giusy Rita Maria La Rosa; Valeria Shumakova; Gaetano Isola; Francesco Indelicato; Calogero Bugea; Eugenio Pedullà
Journal:  Materials (Basel)       Date:  2021-04-27       Impact factor: 3.623

3.  Shaping ability of ProTaper Gold, One Curve, and Self-Adjusting File systems in severely curved canals: A cone-beam computed tomography study.

Authors:  Meenu G Singla; Hemanshi Kumar; Ritika Satija
Journal:  J Conserv Dent       Date:  2021-12-08