Literature DB >> 32164547

Applications of machine learning for simulations of red blood cells in microfluidic devices.

Hynek Bachratý1, Katarína Bachratá1, Michal Chovanec2, Iveta Jančigová1, Monika Smiešková1, Kristína Kovalčíková1.   

Abstract

BACKGROUND: For optimization of microfluidic devices for the analysis of blood samples, it is useful to simulate blood cells as elastic objects in flow of blood plasma. In such numerical models, we primarily need to take into consideration the movement and behavior of the dominant component of the blood, the red blood cells. This can be done quite precisely in small channels and within a short timeframe. However, larger volumes or timescales require different approaches. Instead of simplifying the simulation, we use a neural network to predict the movement of the red blood cells.
RESULTS: The neural network uses data from the numerical simulation for learning, however, the simulation needs only be run once. Alternatively, the data could come from video processing of a recording of a biological experiment. Afterwards, the network is able to predict the movement of the red blood cells because it is a system of bases that gives an approximate cell velocity at each point of the simulation channel as a linear combination of bases.In a simple box geometry, the neural network gives results comparable to predictions using fluid streamlines, however in a channel with obstacles forming slits, the neural network is about five times more accurate.The network can also be used as a discriminator between different situations. We observe about two-fold increase in mean relative error when a network trained on one geometry is used to predict trajectories in a modified geometry. Even larger increase was observed when it was used to predict trajectories of cells with different elastic properties.
CONCLUSIONS: While for uncomplicated box channels there is no advantage in using a system of bases instead of a simple prediction using fluid streamlines, in a more complicated geometry, the neural network is significantly more accurate. Another application of this system of bases is using it as a comparison tool for different modeled situations. This has a significant future potential when applied to processing data from videos of microfluidic flows.

Entities:  

Keywords:  Cell trajectories; Microfluidic device; Neural network; Red blood cell; Simulation of fluid

Mesh:

Year:  2020        PMID: 32164547      PMCID: PMC7068868          DOI: 10.1186/s12859-020-3357-5

Source DB:  PubMed          Journal:  BMC Bioinformatics        ISSN: 1471-2105            Impact factor:   3.169


  14 in total

1.  Analysis of red blood cell deformation under fast shear flow for better estimation of hemolysis.

Authors:  Masanori Nakamura; Sadao Bessho; Shigeo Wada
Journal:  Int J Numer Method Biomed Eng       Date:  2013-08-15       Impact factor: 2.747

2.  How should the optical tweezers experiment be used to characterize the red blood cell membrane mechanics?

Authors:  Julien Sigüenza; Simon Mendez; Franck Nicoud
Journal:  Biomech Model Mechanobiol       Date:  2017-05-03

3.  Effect of spectrin network elasticity on the shapes of erythrocyte doublets.

Authors:  Masoud Hoore; François Yaya; Thomas Podgorski; Christian Wagner; Gerhard Gompper; Dmitry A Fedosov
Journal:  Soft Matter       Date:  2018-08-01       Impact factor: 3.679

4.  How malaria parasites reduce the deformability of infected red blood cells.

Authors:  S Majid Hosseini; James J Feng
Journal:  Biophys J       Date:  2012-07-03       Impact factor: 4.033

5.  Adaptive computation algorithm for RBF neural network.

Authors:  Hong-Gui Han; Jun-Fei Qiao
Journal:  IEEE Trans Neural Netw Learn Syst       Date:  2012-02       Impact factor: 10.451

6.  Healthy and unhealthy red blood cell detection in human blood smears using neural networks.

Authors:  Hany A Elsalamony
Journal:  Micron       Date:  2016-02-01       Impact factor: 2.251

7.  Biophysical isolation and identification of circulating tumor cells.

Authors:  James Che; Victor Yu; Edward B Garon; Jonathan W Goldman; Dino Di Carlo
Journal:  Lab Chip       Date:  2017-04-11       Impact factor: 6.799

8.  Deformability study of breast cancer cells using microfluidics.

Authors:  H W Hou; Q S Li; G Y H Lee; A P Kumar; C N Ong; C T Lim
Journal:  Biomed Microdevices       Date:  2009-06       Impact factor: 2.838

9.  An On-Chip RBC Deformability Checker Significantly Improves Velocity-Deformation Correlation.

Authors:  Chia-Hung Dylan Tsai; Junichi Tanaka; Makoto Kaneko; Mitsuhiro Horade; Hiroaki Ito; Tatsunori Taniguchi; Tomohito Ohtani; Yasushi Sakata
Journal:  Micromachines (Basel)       Date:  2016-10-01       Impact factor: 2.891

10.  Classification of red blood cell shapes in flow using outlier tolerant machine learning.

Authors:  Alexander Kihm; Lars Kaestner; Christian Wagner; Stephan Quint
Journal:  PLoS Comput Biol       Date:  2018-06-15       Impact factor: 4.475

View more
  4 in total

1.  Application of machine learning in predicting blood flow and red cell distribution in capillary vessel networks.

Authors:  Saman Ebrahimi; Prosenjit Bagchi
Journal:  J R Soc Interface       Date:  2022-08-10       Impact factor: 4.293

2.  Intelligent acoustofluidics enabled mini-bioreactors for human brain organoids.

Authors:  Hongwei Cai; Zheng Ao; Zhuhao Wu; Sunghwa Song; Ken Mackie; Feng Guo
Journal:  Lab Chip       Date:  2021-06-01       Impact factor: 7.517

3.  Main findings and advances in bioinformatics and biomedical engineering- IWBBIO 2018.

Authors:  Olga Valenzuela; Fernando Rojas; Ignacio Rojas; Peter Glosekotter
Journal:  BMC Bioinformatics       Date:  2020-05-05       Impact factor: 3.169

Review 4.  Machine Learning-Driven Multiobjective Optimization: An Opportunity of Microfluidic Platforms Applied in Cancer Research.

Authors:  Yi Liu; Sijing Li; Yaling Liu
Journal:  Cells       Date:  2022-03-05       Impact factor: 6.600

  4 in total