| Literature DB >> 32164151 |
Nikolay Samotaev1, Artur Litvinov1, Maya Etrekova1,2, Konstantin Oblov1, Dmitrii Filipchuk1,2, Alexey Mikhailov2.
Abstract
A prototype of a nitro compound vapor and trace detector, which uses the pyrolysis method and a capacitive gas sensor based on the metal-insulator-semiconductor (MIS) structure type Pd-SiO2-Si, was developed and manufactured. It was experimentally established that the detection limit of trinitrotoluene trace for the detector prototype is 1 × 10-9 g, which corresponds to concentration from 10-11 g/cm3 to 10-12 g/cm3. The prototype had a response time of no more than 30 s. The possibility of further improving the characteristics of the prototype detector by reducing the overall dimensions and increasing the sensitivity of the MIS sensors is shown.Entities:
Keywords: MIS structure type Pd–SnO2–SiO2–Si; NO2 gas detection in ppb level; field effect gas sensor; pyrolysis of nitro compound vapor
Year: 2020 PMID: 32164151 DOI: 10.3390/s20051514
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576