Literature DB >> 32160616

Comparing Heads-Up versus Binocular Microscope Visualization Systems in Anterior and Posterior Segment Surgeries: A Retrospective Study.

Florence Berquet1, Adrien Henry2, Coralie Barbe3, Thibault Cheny2, Mickaël Afriat2, Abdel-Karim Benyelles2, David Bartolomeu2, Carl Arndt2.   

Abstract

BACKGROUND: Three-dimensional (3D) visualization systems, also known as heads-up systems, are now available for eye surgery and as with every new device there is need for a specific evaluation.
OBJECTIVES: The aim of this study was to compare the efficiency, surgical comfort, and safety of a 3D visualization system to a standard binocular microscope (BM) in routine ophthalmologic procedures.
METHOD: After a 4-week training period, a 3D visualization system (Ngenuity, Alcon®) available in one of the Robert Debré Hospital Ophthalmology Departments' operating rooms was compared to a standard BM (OPMI LUMIRA 700, Zeiss®), in the process of a call for new device evaluation. From December 2017 to March 2018, 5 surgeons and their respective residents were asked to fill in a questionnaire for all procedures. Before the surgery, the surgeon recorded: (i) the type of surgery (cataract [PK], retinal detachment [RD], epiretinal membrane peeling [ERM], macular hole, vitreous haemorrhage [VH]), (ii) the type of visualization system chosen (3D or BM), and (iii) the estimated surgical risk (low, intermediate, or high grade). At the end of the procedure, the primary surgeon recorded the remaining parameters, including: (i) surgery duration, (ii) intraoperative complications, (iii) percentage of endoillumination for posterior segment surgeries, (iv) status of the operator (senior or resident) and operator switch if necessary (senior only, resident only, or resident with help of the senior), and rated: (i) the visual comfort (low, normal, excellent), (ii) the operative fluency (low, normal, excellent), (iii) backaches (none, low, moderate, important), and (iv) headaches (range from 0 to 10). Age and sex were collected retrospectively. The procedures performed with 3D and BM were subsequently compared using univariate (χ2, Fisher, Wilcoxon) and multivariate analysis (generalized linear model), allowing us to identify parameters independently associated with PK surgery duration.
RESULTS: A total of 102 valid questionnaires, relative to 73 PK and 29 vitreoretinal procedures, respectively, were analysed. As regards PK (3D, n = 25 vs. BM, n = 48), the mean age, sex ratio, surgical risk, intraoperative complications (1/25 vs. 4/48), visual comfort, backaches, and headaches were similar between the two systems. The use of 3D allowed faster PK surgeries (16.44 ± 4.36 vs. 21.44 ± 7.50 min; p = 0.007) and slightly enhanced the operative fluency. In vitreoretinal surgeries (3D, n = 14 vs. BM, n = 15), no obvious differences between the two visualization systems were observed, although the use of the 3D system was found to slightly decrease the operative fluency. Parameters independently associated with PK surgery duration were 3D visualization (β = -4.4 ± 1.4; p = 0.002), high preoperative surgical risk (β = 6.2 ± 2.4; p = 0.012), intraoperative complications (β = 8.7 ± 2.6; p = 0.001), and surgeon status (β = -4.4 ± 1.3; p = 0.001) in univariate and multivariate analysis.
CONCLUSIONS: 3D visualization can be safely used in routine practice. It slightly improves the operative fluency, allowing faster PK surgery.
© 2020 S. Karger AG, Basel.

Entities:  

Keywords:  Cataract surgery; Heads-up surgery; Three-dimensional visualization; Vitreoretinal surgery

Mesh:

Year:  2020        PMID: 32160616     DOI: 10.1159/000507088

Source DB:  PubMed          Journal:  Ophthalmologica        ISSN: 0030-3755            Impact factor:   3.250


  6 in total

1.  Surgery-related characteristics, efficacy, safety and surgical team satisfaction of three-dimensional heads-up system versus traditional microscopic equipment for various vitreoretinal diseases.

Authors:  Xin-Yu Zhao; Qing Zhao; Ning-Ning Li; Li-Hui Meng; Wen-Fei Zhang; Er-Qian Wang; You-Xin Chen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-10-10       Impact factor: 3.535

2.  Comparison of Three-Dimensional Surgical System Versus Binocular Microscope for Clear Corneal Incision in Cataract Surgery.

Authors:  Zehui Zhu; Pingjun Chang; Feng Huang; Songqing Shen; Xiaomeng Zhao; Xinpei Ji; Yun E Zhao
Journal:  Ophthalmol Ther       Date:  2022-06-24

3.  Heads-up 3D viewing system in rhegmatogenous retinal detachment with proliferative vitreoretinopathy - A prospective randomized trial.

Authors:  Deeksha Rani; Atul Kumar; Parijat Chandra; Rohan Chawla; Nasiq Hasan; Divya Agarwal
Journal:  Indian J Ophthalmol       Date:  2021-02       Impact factor: 1.848

4.  Initial experience with three-dimensional heads-up display system for cataract surgery - A comparative study.

Authors:  Jai A Kelkar; Aditya S Kelkar; Mounika Bolisetty
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

5.  Influence of the scleral indentation technique on the re-detachment rate following retinal detachment surgery.

Authors:  Lukas Bisorca-Gassendorf; Kai Januschowski; Philip Wakili; Karl T Boden; Peter Szurman; Annekatrin Rickmann; Rosemarie Schlosser
Journal:  Int J Retina Vitreous       Date:  2022-02-15

6.  3D Visualization System in Descemet Membrane Endothelial Keratoplasty (DMEK): A Six-Month Comparison with Conventional Microscope.

Authors:  Alberto Morelli; Rosangela Ferrandina; Eleonora Favuzza; Michela Cennamo; Rita Mencucci
Journal:  J Clin Med       Date:  2022-07-25       Impact factor: 4.964

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.