Literature DB >> 32157812

Retrospective clinical evaluation of 2- to 6-unit implant-supported fixed partial dentures: Mean follow-up of 9 years.

Bruno R Chrcanovic1, Jenö Kisch1, Christel Larsson1.   

Abstract

BACKGROUND: Implant-supported fixed partial dentures (ISFPDs) are one of the most common options to rehabilitate partially edentulous patients.
PURPOSE: To assess the clinical outcomes of ISFPDs.
METHODS: This retrospective study included all patients treated with ISFPDs with 2 to 6 prosthetic units at one specialist clinic. Implant/prosthesis failure and technical complications were the outcomes analyzed.
RESULTS: Six hundred and forty-two patients with 876 ISFPDs (2241 implants) were included, followed up for 108.0 ± 76.2 months. Eighty-eight prostheses and 112 implants (26 before, 86 after prosthesis installation) failed. The estimated CSR of ISFPDs at 30 years was 72.7%. Smokers presented lower implant survival than nonsmokers. Two hundred and ninety-nine ISFPDs (33.2%) presented technical complications. Bruxism was a factor to exert a higher risk of screw and implant fracture, and ceramic chipping. ISFPDs with cantilever presented higher risk of failure, and screw loosening/fracture. Prostheses supported by implants with internal abutment connection or with two pontics had higher risk of presenting ceramic chipping. Extension of the prosthesis did not seem to exert influence on prosthesis failure/complications.
CONCLUSIONS: ISFPDs presented good long-term prognosis. Implant failure was the main reason for ISFPD failure. The results suggest that bruxism and the presence of cantilever may contribute to the increased rate of mechanical complications and prosthesis failure.
© 2020 The Authors. Clinical Implant Dentistry and Related Research Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  dental implant; fixed partial denture; implant-supported; survival; technical complications

Mesh:

Substances:

Year:  2020        PMID: 32157812     DOI: 10.1111/cid.12889

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  Bond strength of zirconia- or polymer-based copings cemented on implant-supported titanium bases - an in vitro study.

Authors:  Eliann Oddbratt; Lisa Hua; Bruno R Chrcanovic; Evaggelia Papia
Journal:  Biomater Investig Dent       Date:  2021-09-13

Review 2.  Smoking and Dental Implants: A Systematic Review and Meta-Analysis.

Authors:  Abir Dunia Mustapha; Zainab Salame; Bruno Ramos Chrcanovic
Journal:  Medicina (Kaunas)       Date:  2021-12-27       Impact factor: 2.430

Review 3.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.