Literature DB >> 32157452

Graphene oxide/polydimethylsiloxane-coated stainless steel mesh for use in solid-phase extraction cartridges and extraction of polycyclic aromatic hydrocarbons.

Amirhassan Amiri1, Mehdi Baghayeri2, Fatemeh Karimabadi2, Ferial Ghaemi3, Behrooz Maleki2.   

Abstract

The stainless steel mesh, in the form of the disk, was coated with graphene oxide and poly(dimethylsiloxane) (GO-PDMS) by sol-gel technique. The coated stainless steel meshes are loaded in the mini-column as solid-phase extraction cartridge for the fast isolation and preconcentration of polycyclic aromatic hydrocarbons (PAHs) from real water samples. The extracted PAHs (naphthalene, acenaphthene, acenaphthylene, anthracene, benz[a]anthracene, fluorene, and pyrene) were quantified by gas chromatography-mass spectrometry. The operation parameters affecting the extraction efficiency including sample volume, desorption conditions, and ionic strength were investigated. At optimized conditions, the linearity of this method is obtained from 0.001 to 20 ng mL-1 with 0.2 to 1.0 pg mL-1 limit of detection. For 5 replicates at 3 spiking levels (0.1, 1, and 10 ng mL-1), the relative standard deviations between 4.0 and 6.3% were achieved. The absolute extraction recovery varied from 89.1 to 94.7%. The enrichment factors were in the range of 2227-2367. The method has been employed in the determination of PAHs in the real water samples including well water, tap water, river water, and wastewater. Relative recoveries are between 95.2 and 100.9%. Graphical abstractSchematic representation of the SPE procedure using the self-assembly SPE cartridge.

Entities:  

Keywords:  GC-MS; PDMS; SPE; Sample preparation; Sol–gel-based coating; Stainless steel mesh

Year:  2020        PMID: 32157452     DOI: 10.1007/s00604-020-4193-z

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  11 in total

Review 1.  Environmental and bioanalytical applications of hollow fiber membrane liquid-phase microextraction: a review.

Authors:  Jingyi Lee; Hian Kee Lee; Knut E Rasmussen; Stig Pedersen-Bjergaard
Journal:  Anal Chim Acta       Date:  2008-07-06       Impact factor: 6.558

2.  Automated bundled hollow fiber array-liquid-phase microextraction with liquid chromatography tandem mass spectrometric analysis of perfluorinated compounds in aqueous media.

Authors:  Shalene Xue Lin Goh; Hian Kee Lee
Journal:  Anal Chim Acta       Date:  2018-03-22       Impact factor: 6.558

3.  Fabric phase sorptive extraction: a new sorptive microextraction technique for the determination of non-steroidal anti-inflammatory drugs from environmental water samples.

Authors:  Inés Racamonde; Rosario Rodil; José Benito Quintana; Benigno José Sieira; Abuzar Kabir; Kenneth G Furton; Rafael Cela
Journal:  Anal Chim Acta       Date:  2015-01-29       Impact factor: 6.558

4.  Graphene grown on stainless steel mesh as a highly efficient sorbent for sorptive microextraction of polycyclic aromatic hydrocarbons from water samples.

Authors:  Amirhassan Amiri; Ferial Ghaemi
Journal:  Anal Chim Acta       Date:  2017-09-13       Impact factor: 6.558

5.  Improved synthesis of graphene oxide.

Authors:  Daniela C Marcano; Dmitry V Kosynkin; Jacob M Berlin; Alexander Sinitskii; Zhengzong Sun; Alexander Slesarev; Lawrence B Alemany; Wei Lu; James M Tour
Journal:  ACS Nano       Date:  2010-08-24       Impact factor: 15.881

6.  Determination of 16 polycyclic aromatic hydrocarbons in environmental water samples by solid-phase extraction using multi-walled carbon nanotubes as adsorbent coupled with gas chromatography-mass spectrometry.

Authors:  Jiping Ma; Ronghui Xiao; Jinhua Li; Junbao Yu; Yanqing Zhang; Lingxin Chen
Journal:  J Chromatogr A       Date:  2010-06-26       Impact factor: 4.759

7.  Preparation, characterization, and applications of a novel solid-phase microextraction fiber by sol-gel technology on the surface of stainless steel wire for determination of poly cyclic aromatic hydrocarbons in aquatic environmental samples.

Authors:  Ali Es-haghi; Valiallah Hosseininasab; Habib Bagheri
Journal:  Anal Chim Acta       Date:  2014-01-10       Impact factor: 6.558

8.  Applications of polydimethylsiloxane in analytical chemistry: a review.

Authors:  Suresh Seethapathy; Tadeusz Górecki
Journal:  Anal Chim Acta       Date:  2012-05-11       Impact factor: 6.558

9.  Sorptive thin film microextraction followed by direct solid state spectrofluorimetry: A simple, rapid and sensitive method for determination of carvedilol in human plasma.

Authors:  Shima Karimi; Zahra Talebpour; Noushin Adib
Journal:  Anal Chim Acta       Date:  2016-04-25       Impact factor: 6.558

10.  Carbon nanotube-coated solid-phase microextraction metal fiber based on sol-gel technique.

Authors:  Ruifen Jiang; Fang Zhu; Tiangang Luan; Yexiang Tong; Hong Liu; Gangfeng Ouyang; Janusz Pawliszyn
Journal:  J Chromatogr A       Date:  2009-04-01       Impact factor: 4.759

View more