Literature DB >> 32154609

Workplace indoor environmental quality and asthma-related outcomes in healthcare workers.

Steven M Rollins1, Feng-Chiao Su1, Xiaoming Liang1, Michael J Humann1, Aleksandr B Stefaniak1, Ryan F LeBouf1, Marcia L Stanton1, Mohammed A Virji1, Paul K Henneberger1.   

Abstract

BACKGROUND: Asthma-related health outcomes are known to be associated with indoor moisture and renovations. The objective of this study was to estimate the frequency of these indoor environmental quality (IEQ) factors in healthcare facilities and their association with asthma-related outcomes among workers.
METHODS: New York City healthcare workers (n = 2030) were surveyed regarding asthma-related symptoms, and moisture and renovation factors at work and at home during the last 12 months. Questions for workplace moisture addressed water damage (WD), mold growth (MG), and mold odor (MO), while for renovations they addressed painting (P), floor renovations (FR), and wall renovations (WR). Regression models were fit to examine associations between work and home IEQ factors and multiple asthma-related outcomes.
RESULTS: Reports of any moisture (n = 728, 36%) and renovations (n = 1412, 70%) at work were common. Workplace risk factors for asthma-related outcomes included the moisture categories of WD by itself, WD with MO (without MG), and WD with MG and MO, and the renovation category with the three factors P, FR, and WR. Reports of home IEQ factors were less frequent and less likely to be associated with health outcomes. Data analyses suggested that MG and/or MO at work and at home had a synergistic effect on the additive scale with a symptom-based algorithm for bronchial hyperresponsiveness.
CONCLUSIONS: The current study determined that moisture and renovation factors are common in healthcare facilities, potentially putting workers at risk for asthma-related outcomes. More research is needed to confirm these results, especially prospective studies. Published 2020. This article is a U.S. Government work and is in the public domain in the USA.

Entities:  

Keywords:  healthcare; indoor environmental quality; mold; renovations; work-related asthma

Mesh:

Year:  2020        PMID: 32154609      PMCID: PMC7437141          DOI: 10.1002/ajim.23101

Source DB:  PubMed          Journal:  Am J Ind Med        ISSN: 0271-3586            Impact factor:   3.079


  30 in total

1.  Interaction as departure from additivity in case-control studies: a cautionary note.

Authors:  Anders Skrondal
Journal:  Am J Epidemiol       Date:  2003-08-01       Impact factor: 4.897

Review 2.  An official american thoracic society statement: work-exacerbated asthma.

Authors:  Paul K Henneberger; Carrie A Redlich; David B Callahan; Philip Harber; Catherine Lemière; James Martin; Susan M Tarlo; Olivier Vandenplas; Kjell Torén
Journal:  Am J Respir Crit Care Med       Date:  2011-08-01       Impact factor: 21.405

3.  Dampness, mould, onset and remission of adult respiratory symptoms, asthma and rhinitis.

Authors:  Juan Wang; Mihkel Pindus; Christer Janson; Torben Sigsgaard; Jeong-Lim Kim; Mathias Holm; Johan Sommar; Hans Orru; Thorarinn Gislason; Ane Johannessen; Randi J Bertelsen; Dan Norbäck
Journal:  Eur Respir J       Date:  2019-05-23       Impact factor: 16.671

4.  Respiratory symptoms and respiratory-related absence from work among health care workers in Sweden.

Authors:  Jeong-Lim Kim; Kjell Torén; Susanna Lohman; Linda Ekerljung; Jan Lötvall; Bo Lundbäck; Eva Andersson
Journal:  J Asthma       Date:  2013-02-01       Impact factor: 2.515

5.  Operational definitions of asthma in studies on its aetiology.

Authors:  J Pekkanen; J Sunyer; J M Anto; P Burney
Journal:  Eur Respir J       Date:  2005-07       Impact factor: 16.671

6.  The European Community Respiratory Health Survey.

Authors:  P G Burney; C Luczynska; S Chinn; D Jarvis
Journal:  Eur Respir J       Date:  1994-05       Impact factor: 16.671

7.  Occupation and task as risk factors for asthma-related outcomes among healthcare workers in New York City.

Authors:  Morgan N Caridi; Michael J Humann; Xiaoming Liang; Feng-Chiao Su; Aleksandr B Stefaniak; Ryan F LeBouf; Marcia L Stanton; M Abbas Virji; Paul K Henneberger
Journal:  Int J Hyg Environ Health       Date:  2018-10-13       Impact factor: 5.840

8.  Asthma score: predictive ability and risk factors.

Authors:  J Sunyer; J Pekkanen; R Garcia-Esteban; C Svanes; N Künzli; C Janson; R de Marco; J M Antó; P Burney
Journal:  Allergy       Date:  2007-02       Impact factor: 13.146

9.  Clustering asthma symptoms and cleaning and disinfecting activities and evaluating their associations among healthcare workers.

Authors:  Feng-Chiao Su; Melissa C Friesen; Michael Humann; Aleksandr B Stefaniak; Marcia L Stanton; Xiaoming Liang; Ryan F LeBouf; Paul K Henneberger; M Abbas Virji
Journal:  Int J Hyg Environ Health       Date:  2019-04-19       Impact factor: 5.840

10.  Asthma and respiratory symptoms in hospital workers related to dampness and biological contaminants.

Authors:  J M Cox-Ganser; C Y Rao; J-H Park; J C Schumpert; K Kreiss
Journal:  Indoor Air       Date:  2009-01-18       Impact factor: 5.770

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.