Room-temperature X-ray response of cadmium-zinc-telluride pixel detectors grown by the vertical Bridgman technique.

Leonardo Abbene1, Fabio Principato1, Gaetano Gerardi1, Antonino Buttacavoli1, Donato Cascio1, Manuele Bettelli2, Nicola Sarzi Amadè2, Paul Seller3, Matthew C Veale3, Oliver Fox4, Kawal Sawhney4, Silvia Zanettini5, Elio Tomarchio6, Andrea Zappettini2.   

Abstract

In this work, the spectroscopic performances of new cadmium-zinc-telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm-1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation of the charge losses at the inter-pixel gap region. High-rate measurements demonstrated the absence of high-flux radiation-induced polarization phenomena up to 2 × 106 photons mm-2 s-1. These activities are in the framework of an international collaboration on the development of energy-resolved photon-counting systems for high-flux energy-resolved X-ray imaging.

Entities:  

Keywords:  CdZnTe pixel detectors; X-ray and gamma-ray detectors; charge losses; charge sharing; spectroscopic X-ray imaging; vertical Bridgman technique

Year:  2020        PMID: 32153270     DOI: 10.1107/S1600577519015996

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  4 in total

1.  Ballistic Deficit Pulse Processing in Cadmium-Zinc-Telluride Pixel Detectors for High-Flux X-ray Measurements.

Authors:  Antonino Buttacavoli; Fabio Principato; Gaetano Gerardi; Manuele Bettelli; Andrea Zappettini; Paul Seller; Matthew C Veale; Silvia Zanettini; Leonardo Abbene
Journal:  Sensors (Basel)       Date:  2022-04-29       Impact factor: 3.847

2.  Fabrication of Small-Pixel CdZnTe Sensors and Characterization with X-rays.

Authors:  Stergios Tsigaridas; Silvia Zanettini; Manuele Bettelli; Nicola Sarzi Amadè; Davide Calestani; Cyril Ponchut; Andrea Zappettini
Journal:  Sensors (Basel)       Date:  2021-04-22       Impact factor: 3.576

3.  Incomplete Charge Collection at Inter-Pixel Gap in Low- and High-Flux Cadmium Zinc Telluride Pixel Detectors.

Authors:  Antonino Buttacavoli; Fabio Principato; Gaetano Gerardi; Donato Cascio; Giuseppe Raso; Manuele Bettelli; Andrea Zappettini; Paul Seller; Matthew C Veale; Leonardo Abbene
Journal:  Sensors (Basel)       Date:  2022-02-13       Impact factor: 3.576

4.  Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT.

Authors:  Leonardo Abbene; Fabio Principato; Antonino Buttacavoli; Gaetano Gerardi; Manuele Bettelli; Andrea Zappettini; Saverio Altieri; Natalia Auricchio; Ezio Caroli; Silvia Zanettini; Nicoletta Protti
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576