Literature DB >> 3215322

Distal anastomotic intimal hyperplasia: biogenesis and etiology.

V S Sottiurai1, S L Sue, E L Feinberg, W L Bringaze, A T Tran, R C Batson.   

Abstract

Anastomotic intimal hyperplasia occurred exclusively at the heel and the toe plus the floor of the distal end-to-side anastomosis of canine autologous femoro-femoral bypass (n = 14) and not in the end-to-end carotid or femoral interposition graft (n = 14). The occurrence of anastomotic intimal hyperplasia in the absence of compliance mismatch in an autologous bypass suggests that the geometry of the end-to-side anastomosis is primarily responsible for intimal hyperplasia formation. It is believed that because an end-to-side distal anastomosis is not a natural occurrence it is conductive to turbulent flow. The latter causes endothelial injury which in turn allows platelet growth factor to incite subendothelial myoblasts in extracellular matrix synthesis and intimal hyperplasia formation. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) identify myofibroblasts and fibrocollagenous matrix as the dominant cellular and extracellular substances in anastomotic intimal hyperplasia.

Entities:  

Mesh:

Year:  1988        PMID: 3215322     DOI: 10.1016/s0950-821x(88)80034-3

Source DB:  PubMed          Journal:  Eur J Vasc Surg        ISSN: 0950-821X


  9 in total

1.  Microscopic and immunohistological studies on intimal hyperplasia of the arterially implanted autovein graft and its anastomosis in dogs.

Authors:  D R Shrestha; H Shiroma; Y Kamada; A Kusaba
Journal:  Surg Today       Date:  1992       Impact factor: 2.549

Review 2.  Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts.

Authors:  YeJin Jeong; Yuan Yao; Evelyn K F Yim
Journal:  Biomater Sci       Date:  2020-07-09       Impact factor: 6.843

3.  Asynchronous Pumping of a Pulsatile Ventricular Assist Device in a Pediatric Anastomosis Model.

Authors:  Bryan C Good; William J Weiss; Steven Deutsch; Keefe B Manning
Journal:  World J Pediatr Congenit Heart Surg       Date:  2017-07

4.  Biomechanics and biocompatibility of the perfect conduit-can we build one?

Authors:  Michael J Byrom; Martin K C Ng; Paul G Bannon
Journal:  Ann Cardiothorac Surg       Date:  2013-07

5.  Computer assisted Doppler waveform analysis and ultrasound derived turbulence intensity ratios can predict early hyperplasia development in newly created vascular access fistula: Pilot study, methodology and analysis.

Authors:  Matthew Bartlett; Vanessa Diaz-Zuccarini; Janice Tsui
Journal:  JRSM Cardiovasc Dis       Date:  2021-03-20

Review 6.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

7.  End-to-side Anastomosis on Digital Arteries: Just a Technical Choice or a Real Benefit?

Authors:  Luigi Troisi; Erica Tedone Clemente; Valentina Susca; Macarena Vizcay; Francesco Zanchetta; Sara Stucchi; Giorgio Eugenio Pajardi
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-09-30

Review 8.  Analysis of arterial intimal hyperplasia: review and hypothesis.

Authors:  Vladimir M Subbotin
Journal:  Theor Biol Med Model       Date:  2007-10-31       Impact factor: 2.432

9.  Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts.

Authors:  Thomas Frauenfelder; Evangelos Boutsianis; Thomas Schertler; Lars Husmann; Sebastian Leschka; Dimos Poulikakos; Borut Marincek; Hatem Alkadhi
Journal:  Biomed Eng Online       Date:  2007-09-26       Impact factor: 2.819

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.