| Literature DB >> 32151031 |
Janusz Brol1, Jan Kubica1, Marek Węglorz1.
Abstract
This paper presents a discussion of the problem of compressive strength in a direction perpendicular to the grains based on test results of the joints made by timber posts and sill plate. These tests accompanied a larger series of full-scale tests of timber frame walls. The test elements were made of solid softwood (spruce). The wood moisture was low, which corresponds to the real working conditions of these elements in the walls of a building (low humidity is typical for dry wood in the built-in wall of a real building). In the tests, the compression strength of timber perpendicular to the grain was exceeded in the sill plate in the area in contact with the posts. Shortly before reaching the state of failure, large displacements in the sill plate were measured on the contact surface with the post, and the grains in the sill plates were cut off at the edge of the post. The full-scale test results showed an overestimation of the load-bearing capacity in compression perpendicular to the grain when calculated on the basis of EN 1995-1-1+A1:2008 (Eurocode 5), and, therefore, the need to modify the current approach for determining it.Entities:
Keywords: Eurocode 5; compression perpendicular to the grain; effective contact area; spruce; timber
Year: 2020 PMID: 32151031 PMCID: PMC7085190 DOI: 10.3390/ma13051160
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Loading conditions in case with continuous supports according to EN 1995-1-1+A1:2008 [4].
Figure 2Determination of F90 according to EN408+A1:2012 [17].
Figure 3Schematic of the bottom part of the test stand: (a) Series 1, (b) Series 2, (dimensions in mm).
Figure 4The top part of the test stand (load distribution): (a) Series 1, (b) Series 2 (photographs by Brol).
Figure 5The bottom part of the test stand, support conditions: (a) Series 1 (painting is due to the ARAMIS DIC), (b) Series 2 (photographs by Brol).
Figure 6The arrangement of the external LVDTs: (a) joint L, (b) joint R (photographs by Węglorz).
Figure 7Exemplary force (F)–displacement Δh plot of the sill plate at the connection with the post (joint 1.15L).
The test results of the post–sill plate joints.
| Timber Frame Wall Member Number | Proportional Limit | |||
|---|---|---|---|---|
| Series 1 | Series 2 | |||
| Joint “L” | Joint “R” | Joint “L” | Joint “R” | |
| 1 | 42.24 | 46.01 | 26.07 | 35.08 |
| 2 | 38.21 | 38.93 | 28.35 | 29.04 |
| 3 | 26.84 | 32.91 | 26.33 | 27.84 |
| 4 | 44.39 | 44.39 | 26.53 | 26.66 |
| 5 | 26.18 | 28.12 | 32.49 | 31.48 |
| 6 | 37.34 | 36.85 | 31.07 | 28.04 |
| 7 | 30.20 | 34.71 | 38.23 | 38.40 |
| 8 | 26.93 | 25.22 | 41.65 | 43.70 |
| 9 | 27.99 | 26.02 | 34.16 | 39.55 |
| 10 | 23.92 | 47.29 | 42.38 | 41.28 |
| 11 | 25.95 | 27.04 | 35.06 | 37.06 |
| 12 | 28.20 | 38.83 | 35.93 | 36.44 |
| 13 | 38.69 | 36.34 | 48.89 | 46.92 |
| 14 | 26.93 | 32.32 | 32.11 | 31.45 |
| 15 | 38.15 | 28.36 | 41.68 | 33.98 |
| 16 | 27.81 | 28.02 | 40.80 | 41.21 |
The statistical analysis of the test results.
| Statistical Value | Series 1 | Series 2 |
|---|---|---|
| Mean compression force perpendicular to the grain, | 33.17 | 35.31 |
| Maximum compression force perpendicular to the grain, | 47.29 | 48.89 |
| Minimum compression force perpendicular to the grain, | 23.92 | 26.07 |
| Standard deviation, | 6.98 | 6.34 |
| The | 1.33 | 1.46 |
| 2.02 | 2.14 | |
| Coefficient of variation | 0.21 | 0.18 |
| Characteristic compression force perpendicular to the grain, | 21.10 | 24.34 |
Figure 8The F–displacement, Δh plot of the sill plate at the connection with the post: (a) Series 1 results and regression curve, (b) Series 2 results and regression curve. The mean compression force perpendicular to the grain, F90, according to Table 2.
Figure 9The failure mode of the joints of the timber frame wall members: (a) Series 1, (b) Series 2 (photographs by Brol).
Figure 10Exemplary displacements dX at the edge of the sill plate (joint 2.4L), over the duration of the test (ARAMIS DIC): (a) reference points and their trajectories (green), (b) deformation plot. The force F = 26.78 kN at total DIC running time (1015.403 s) is marked by the vertical line (red).
Figure 11Exemplary displacements dX at the edge of the sill plate (joint 2.4R), over the duration of the test (ARAMIS DIC): (a) reference points and their trajectories (green), (b) deformation plot. The force F = 26.78 kN at total DIC running time (1015.403 s) is marked by the vertical line (red).
Figure 12Trail specimen dimensions specified for the calculation of the effective contact area, A according to EN 1995-1-1+A1:2008 [4] (dimensions in mm).
A comparison of the test results and Eurocode 5.
| Feature | |||||
|---|---|---|---|---|---|
| Series 1 | Series 2 | Eurocode 5 | Series 1 | Series 2 | |
| Characteristic compression force perpendicular to the grain | 21.10 | 24.34 | 35.0 | 0.60 | 0.70 |