Literature DB >> 32146438

Risk assessment of the total testing process based on quality indicators with the Sigma metrics.

Yong Xia1, Xiaoxue Wang1, Cunliang Yan1, Jinbin Wu1, Hao Xue1, Mingyang Li1, Yu Lin1, Jie Li2, Ling Ji3.   

Abstract

Background Evidence-based evaluation of laboratory performances including pre-analytical, analytical and post-analytical stages of the total testing process (TTP) is crucial to ensure patients receiving safe, efficient and effective care. To conduct risk assessment, quality management tools such as Failure Mode and Effect Analysis (FMEA) and the Failure Reporting and Corrective Action System (FRACAS) were constantly used for proactive or reactive analysis, respectively. However, FMEA and FRACAS faced big challenges in determining the scoring scales and failure prioritization in the assessment of real-world cases. Here, we developed a novel strategy, by incorporating Sigma metrics into risk assessment based on quality indicators (QIs) data, to provide a more objective assessment of risks in TTP. Methods QI data was collected for 1 year and FRACAS was applied to produce the risk rating based on three variables: (1) Sigma metrics for the frequency of defects; (2) possible consequence; (3) detection method. The risk priority number (RPN) of each QI was calculated by a 5-point scale score, where a value of RPN > 50 was rated as high-risk. Results The RPNs of two QIs in post-analytical phase (TAT of Stat biochemistry analyte and Timely critical values notification) were above 50 which required rigorous monitoring and corrective actions to eliminate the high risks. Nine QIs (RPNs between 25 and 50) required further investigation and monitoring. After 3 months of corrective action the two identified high-risk processes were successfully reduced. Conclusions The strategy can be implemented to reduce identified risk and assuring patient safety.

Entities:  

Keywords:  Failure Mode and Effect Analysis; Failure Reporting and Corrective Action System; Quality Indicators; Sigma metrics; risk assessment; total testing process

Year:  2020        PMID: 32146438     DOI: 10.1515/cclm-2019-1190

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Real-world use of key performance indicators for point-of-Care Testing network accredited by ISO 22870.

Authors:  Paloma Oliver; Pilar Fernandez-Calle; Roberto Mora; Jorge Diaz-Garzon; Daniel Prieto; Marta Manzano; Inmaculada Dominguez; Antonio Buño
Journal:  Pract Lab Med       Date:  2020-11-06

2.  Six Sigma performance of quality indicators in total testing process of point-of-care glucose measurement: A two-year review.

Authors:  Anne Vincent; Donnah Pocius; Yun Huang
Journal:  Pract Lab Med       Date:  2021-03-19

3.  Development and Application of Computerized Risk Registry and Management Tool Based on FMEA and FRACAS for Total Testing Process.

Authors:  Jeonghyun Chang; Soo Jin Yoo; Sollip Kim
Journal:  Medicina (Kaunas)       Date:  2021-05-11       Impact factor: 2.430