Literature DB >> 32132736

NEUTROPHIL SCATTERING DATA DRIVEN PRE-MICROSCOPIC FLAGGING OF ACUTE LEUKEMIC CASES.

Rana Zeeshan-Haider1,2,3, Eloisa Urrechaga4, Ikram Uddin-Ujjan5, Tahir Sultan-Shamsi1.   

Abstract

BACKGROUND: The hematology analyzer, Sysmex XN-1000, generates white blood cell count with varying scattering intensities during a complete blood count (CBC) analysis.
OBJECTIVES: The objectives of the study were to study the predictive role of median and coefficient of variation of neutrophil scattering items in blood samples for differentiation of leukemic subjects.
METHODS: We evaluated six neutrophil scattering parameters: neutrophil side scatter mean intensity, neutrophil side fluorescence light (SFL) mean intensity, neutrophil forward scatter mean intensity, neutrophil side scatter area distribution width (NE-WX), neutrophil SFL area distribution width (NE-WY), and neutrophil forward scatter area distribution width (NE-WZ), measured in white blood cell differential scattergram generated by the hematology analyzer (Sysmex XN-1000) at an academic medical center.
RESULTS: We collected 433 blood samples from acute myeloid leukemia (AML) and acute lymphoid leukemia (ALL) cases and normal controls. AML group showed highly significant differences in the mean values compared with the control group. Out of six neutrophil scattering items, NE-WX, NE-WY, and NE-WZ showed high efficiency, with area under the curve (AUC) values of 0.764, 0.748, and 0.757, respectively, to differentiate AML from ALL cases and control groups. When comparing combined acute leukemia cases (AML plus ALL) with the control group, NE-WX, NE-WY, and NE-WZ generated highly significant AUC values (0.840, 0.884, and 0.801, respectively).
CONCLUSION: The neutrophil scattering parameters generated during CBC analysis provide a new tool for the prediction of acute leukemia and its lineage. Copyright:
© 2019 Permanyer.

Entities:  

Keywords:  Acute leukemia; Hematology analyzer; Neutrophil scattering items; Sysmex

Mesh:

Year:  2020        PMID: 32132736     DOI: 10.24875/RIC.19003194

Source DB:  PubMed          Journal:  Rev Invest Clin        ISSN: 0034-8376            Impact factor:   1.451


  1 in total

1.  Usefulness of Leucocyte Cell Population Data by Sysmex XN1000 Hematology Analyzer in Rapid Identification of Acute Leukemia.

Authors:  Shruti Mishra; Gaurav Chhabra; Somanath Padhi; Sonali Mohapatra; Ashutosh Panigrahi; Mukund Namdev Sable; Prabodha Kumar Das
Journal:  Indian J Hematol Blood Transfus       Date:  2021-09-28       Impact factor: 0.915

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.