Effect of dynamic position changes during colonoscope withdrawal: a meta-analysis of randomized controlled trials.

Peiwen Li1, Bin Ma2, Shulei Gong1, Xinyu Zhang1, Wenya Li3.   

Abstract

BACKGROUND: Colonoscopies are considered to be the primary screening test and gold standard test for colorectal cancer. Position changes during colonoscope withdrawal are believed to be associated with an increased adenoma detection rate (ADR) and polyp detection rate (PDR). However, previous results conflicted, and this study aimed to elucidate the effectiveness of dynamic position changes during colonoscope withdrawal.
METHODS: The relevant publications were identified by searching the medical databases. The primary outcomes were the ADR and PDR, which were pooled and analyzed. The secondary outcome was the withdrawal time. The studies that supplied the ADR and PDR for different segments of the colon were separated into subgroup analyses.
RESULTS: Five randomized controlled trials were eligible for analysis. The total ADR was higher with dynamic position changes than with a static position (odds ratio, [OR] 1.34; 95% confidence interval [CI] 1.13-1.59; p < 0.001), with low evidence of between-study heterogeneity (I2 = 0%). Although the total PDR was slightly higher with dynamic position changes than with a static position (OR 1.23; 95% CI 0.88-1.73), there difference was not statistically significant (p = 0.22). The withdrawal time was only increased by 0.47 min (95% CI - 0.11 to 1.06) with dynamic position changes, without statistical significance (p = 0.11). The subgroup analysis showed that the ADR and PDR for the transverse colon were higher with dynamic position changes, with pooled estimates of ADR (OR 1.72; 95% CI 1.02-2.88; p = 0.04) and PDR (OR 1.79; 95% CI 1.08-2.96; p = 0.02).
CONCLUSION: Dynamic position changes during colonoscope withdrawal increased the total ADR; however, no obvious increase was found in the total PDR. The withdrawal time was not significantly prolonged with dynamic position changes. Subgroup analysis showed that the ADR and PDR in the transverse colon were obviously improved with dynamic position changes.

Entities:  

Keywords:  Adenoma detection rate; Colonoscopy; Dynamic position changes; Polyp detection rate

Mesh:

Year:  2020        PMID: 32128607     DOI: 10.1007/s00464-020-07483-x

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  4 in total

1.  The Impact of the Colonoscopy Starting Position and Its Potential Outcomes.

Authors:  Pallavi Shah; Nehal Patel; Alhareth Alsayed; Steven Miller; Nitish Singh Nandu
Journal:  Cureus       Date:  2022-05-14

2.  Comparison of adenoma detection in different colorectal segments between deep-sedated and unsedated colonoscopy.

Authors:  Yue Sui; Qing Wang; Hai-Hua Chen; Jun-Hui Lu; Qing Wen; Zhen-Zhen Wang; Guan-Feng Wang; Hui Jia; Tao Xiao; Na-Ping Wang; Jun-Lian Hao; Yi-Ping Zhang; Feng-Zhen Cao; Xiao-Peng Wu; Xing Chen
Journal:  Sci Rep       Date:  2022-09-12       Impact factor: 4.996

3.  Comparison of three sedation models for same-day painless bidirectional endoscopy: A multicenter randomized controlled trial.

Authors:  Yue Sui; Xing Chen; Ting Ma; Junhui Lu; Tao Xiao; Zhenzhen Wang; Qing Wen; Guanfeng Wang; Hui Jia; Fengzhen Cao; Xiaopeng Wu; Yiping Zhang; Junlian Hao; Naping Wang
Journal:  J Gastroenterol Hepatol       Date:  2022-06-02       Impact factor: 4.369

4.  Development and validation of a patient-reported scale for tolerability of endoscopic procedures using conscious sedation.

Authors:  Nauzer Forbes; Millie Chau; Hannah F Koury; B Cord Lethebe; Zachary L Smith; Sachin Wani; Rajesh N Keswani; B Joseph Elmunzer; John T Anderson; Steven J Heitman; Robert J Hilsden
Journal:  Gastrointest Endosc       Date:  2020-12-30       Impact factor: 9.427

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.