Literature DB >> 32126291

Long-term results after semiconstrained distal radioulnar joint arthroplasty: A focus on complications.

N Fuchs1, L A Meier2, T Giesen3, M Calcagni4, L Reissner5.   

Abstract

Arthroplasty of the distal radioulnar joint (DRUJ) using a semiconstrained DRUJ implant yields good outcomes according to the literature. The aim of this study was to investigate the subjective, clinical and radiographic outcomes with a special focus on complications in nine patients with a mean follow-up of 6years and to compare them with our previously published 3-year follow-up results. No subjective or objective changes were seen between the 3-year and the 6-year follow-up. In the previous study, one implant loosening and two irritations of the superficial branch of the radial nerve occurred. We saw three complications that needed surgery in addition to the three complications already found 3years after surgery. One patient with a large ulna had loosening of the cemented ulnar stem and therefore the prosthesis was explanted. One patient had an allergic reaction to the metal alloy of the prosthesis, which also led to removal. One patient had an ulnar impaction syndrome caused by too-distal placement of the implant that needed revision. Prior studies reported low complication rates. In our study, six complications occurred in four out of nine patients, requiring reoperation including two revisions and two implant removals. A precise surgical technique is mandatory to avoid the otherwise frequent complications and potential implant failures. LEVEL OF EVIDENCE: IV.
Copyright © 2020 SFCM. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Aptis prosthesis; Arthroplastie; Arthroplasty; Articulation radio-ulnaire distale; Distal radioulnar joint; Implant semi-contraint; Prothèse Aptis; Prothèse de Scheker; Scheker prosthesis; Semiconstrained implant

Year:  2020        PMID: 32126291     DOI: 10.1016/j.hansur.2020.01.010

Source DB:  PubMed          Journal:  Hand Surg Rehabil        ISSN: 2468-1210            Impact factor:   0.969


  3 in total

1.  Midterm Functional Outcome of the Linked Semiconstrained Distal Radioulnar Joint Prosthesis.

Authors:  Jaak Warlop; Maarten Van Nuffel; Luc De Smet; Ilse Degreef
Journal:  J Wrist Surg       Date:  2021-12-13

2.  3D analysis of the distal ulna with regard to the design of a new ulnar head prosthesis.

Authors:  Pascal Raffael Furrer; Ladislav Nagy; Lisa Reissner; Andreas Schweizer
Journal:  BMC Musculoskelet Disord       Date:  2022-06-02       Impact factor: 2.562

3.  Finite element analysis of intraosseous distal radioulnar joint prosthesis.

Authors:  Farzaneh Gholamian; Mehran Ashrafi; Ali Moradi
Journal:  BMC Musculoskelet Disord       Date:  2022-08-17       Impact factor: 2.562

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.