Preoperative bedside ultrasound assessment of gastric volume and evaluation of predisposing factors for delayed gastric emptying: a case-control observational study.

Helena Valero Castañer1, Marina Vendrell Jordà2, Xavier Sala Blanch3, Ricard Valero3.   

Abstract

Perioperative pulmonary aspiration of gastric content is a serious complication. Fasting guidelines try to ensure an empty stomach before intervention. Certain medications or pathologies may cause delayed gastric emptying. Bedside ultrasonography is a useful tool when gastric content status is unclear or in emergency situations where fasting is not feasible. The aim of this prospective case-control observational study was to assess differences in gastric fluid volume between fasted patients with or without predisposing factors for delayed gastric emptying. Patients were preoperatively scanned. Antral cross-sectional area was measured by two tracing methods and total gastric clear fluid volumes were calculated. Data was recorded from September 2018 to March 2019 in a university hospital setting in Barcelona, Spain. Fifty-three patients were enrolled, 23 with delayed gastric emptying predisposing factors (DGEF) and 30 without non-DGEF. Ultrasound-estimated gastric clear fluid volume was 35.21 ± 32.69 mL in the DGEF versus 53.50 ± 30.72 mL in the non-DGEF group (p = 0.08). Average volume per unit of weight was 0.61 ± 0.46 mL/kg. Only 1 patient in the DGEF group had a volume that posed a higher risk of aspiration (1.57 mL/kg). Perfect correlation (R = 0.91; p < 0.01) and concordance (0.91; 95% CI 0.83; 0.95) was found between tracing methods. Minimal gastric content was observed in scheduled surgery in spite of predisposing factors for delayed gastric emptying. Ultrasound clear gastric volume estimation was useful to assess preoperative bedside gastric content.

Entities:  

Keywords:  Bronchoaspiration; Diabetes; Gastric ultrasound; Preoperative assessment

Year:  2020        PMID: 32124149     DOI: 10.1007/s10877-020-00489-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  1 in total

1.  Comparison of gastric insufflation using LMA-supreme and I-gel versus tracheal intubation in laparoscopic gynecological surgery by ultrasound: a randomized observational trial.

Authors:  Qiuping Ye; Di Wu; Weiping Fang; Gordon Tin Chun Wong; Yao Lu
Journal:  BMC Anesthesiol       Date:  2020-06-03       Impact factor: 2.217