Literature DB >> 32122001

Simultaneous measurement of gas absorption and path length by employing the first harmonic phase angle method in wavelength modulation spectroscopy.

Chenguang Yang, Liang Mei, Xingping Wang, Hao Deng, Mai Hu, Zhenyu Xu, Bing Chen, Yabai He, Ruifeng Kan.   

Abstract

Tunable diode laser absorption spectroscopy has been widely employed for gas sensing, where the gas concentration is often obtained from the absorption signal with a known or a fixed absorption path length. Nevertheless, there are also numerous applications in which the absorption path length is very challenging to retrieve, e.g., open path remote sensing and gas absorption in scattering media. In this work, a new approach, based on the wavelength modulation spectroscopy (WMS), has been developed to measure the gas absorption signal and the corresponding absorption path length simultaneously. The phase angle of the first harmonic signal (1f phase angle) in the WMS technique is utilized for retrieving the absorption path length as well as the gas absorption signal. This approach has been experimentally validated by measuring carbon dioxide (CO2) concentration in open path environment. The CO2 concentration is evaluated by measuring the reflectance signal from a distant object with hundreds of meters away from the system. The measurement accuracy of the absorption path length, evaluated from a 7-day continuous measurement, can reach up to 1%. The promising result has shown a great potential of utilizing the 1f phase angle for gas concentration measurements, e.g., open path remote sensing applications.

Entities:  

Year:  2020        PMID: 32122001     DOI: 10.1364/OE.383744

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  2 in total

1.  Development of a Laser Gas Analyzer for Fast CO2 and H2O Flux Measurements Utilizing Derivative Absorption Spectroscopy at a 100 Hz Data Rate.

Authors:  Mingxing Li; Ruifeng Kan; Yabai He; Jianguo Liu; Zhenyu Xu; Bing Chen; Lu Yao; Jun Ruan; Huihui Xia; Hao Deng; Xueli Fan; Bangyi Tao; Xueling Cheng
Journal:  Sensors (Basel)       Date:  2021-05-13       Impact factor: 3.576

2.  Compact Open-Path Sensor for Fast Measurements of CO2 and H2O using Scanned-Wavelength Modulation Spectroscopy with 1f-Phase Method.

Authors:  Xiang Li; Feng Yuan; Mai Hu; Bin Chen; Yabai He; Chenguang Yang; Lifang Shi; Ruifeng Kan
Journal:  Sensors (Basel)       Date:  2020-03-30       Impact factor: 3.576

  2 in total