Literature DB >> 32121672

Sleep Apnea Detection with Polysomnography and Depth Sensors.

Martin Schätz1, Aleš Procházka1,2,3, Jiří Kuchyňka3, Oldřich Vyšata1,3.   

Abstract

This paper is devoted to proving two goals, to show that various depth sensors can be used to record breathing rate with the same accuracy as contact sensors used in polysomnography (PSG), in addition to proving that breathing signals from depth sensors have the same sensitivity to breathing changes as in PSG records. The breathing signal from depth sensors can be used for classification of sleep [d=R2]apneaapnoa events with the same success rate as with PSG data. The recent development of computational technologies has led to a big leap in the usability of range imaging sensors. New depth sensors are smaller, have a higher sampling rate, with better resolution, and have bigger precision. They are widely used for computer vision in robotics, but they can be used as non-contact and non-invasive systems for monitoring breathing and its features. The breathing rate can be easily represented as the frequency of a recorded signal. All tested depth sensors (MS Kinect v2, RealSense SR300, R200, D415 and D435) are capable of recording depth data with enough precision in depth sensing and sampling frequency in time (20-35 frames per second (FPS)) to capture breathing rate. The spectral analysis shows a breathing rate between 0.2 Hz and 0.33 Hz, which corresponds to the breathing rate of an adult person during sleep. To test the quality of breathing signal processed by the proposed workflow, a neural network classifier (simple competitive NN) was trained on a set of 57 whole night polysomnographic records with a classification of sleep [d=R2]apneaapnoas by a sleep specialist. The resulting classifier can mark all [d=R2]apneaapnoa events with 100% accuracy when compared to the classification of a sleep specialist, which is useful to estimate the number of events per hour. [d=R2]When compared to the classification of polysomnographic breathing signal segments by a sleep specialistand, which is used for calculating length of the event, the classifier has an [d=R1] F 1 score of 92.2%Accuracy of 96.8% (sensitivity 89.1% and specificity 98.8%). The classifier also proves successful when tested on breathing signals from MS Kinect v2 and RealSense R200 with simulated sleep [d=R2]apneaapnoa events. The whole process can be fully automatic after implementation of automatic chest area segmentation of depth data.

Entities:  

Keywords:  breathing analysis; computational intelligence; depth sensors; human-machine interaction; image processing; signal processing

Year:  2020        PMID: 32121672     DOI: 10.3390/s20051360

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  4 in total

Review 1.  Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration.

Authors:  Haythem Rehouma; Rita Noumeir; Sandrine Essouri; Philippe Jouvet
Journal:  Sensors (Basel)       Date:  2020-12-17       Impact factor: 3.576

2.  Fiber-Optic Based Smart Textiles for Real-Time Monitoring of Breathing Rate.

Authors:  Aizhan Issatayeva; Aidana Beisenova; Daniele Tosi; Carlo Molardi
Journal:  Sensors (Basel)       Date:  2020-06-17       Impact factor: 3.576

Review 3.  The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise.

Authors:  Andrea Nicolò; Carlo Massaroni; Emiliano Schena; Massimo Sacchetti
Journal:  Sensors (Basel)       Date:  2020-11-09       Impact factor: 3.576

Review 4.  Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature.

Authors:  Anthony P Addison; Paul S Addison; Philip Smit; Dominique Jacquel; Ulf R Borg
Journal:  Sensors (Basel)       Date:  2021-02-06       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.