Literature DB >> 32113770

Multiplex loop-mediated isothermal amplification-based lateral flow dipstick for simultaneous detection of 3 food-borne pathogens in powdered infant formula.

Yujun Jiang1, Sihan Chen1, Yueming Zhao1, Xinyan Yang1, Shiqian Fu1, John L McKillip2, Edward M Fox3, Chaoxin Man4.   

Abstract

In this study, we established a rapid, simple, and sensitive method for visual and point-of-care detection of Salmonella spp., Cronobacter spp., and Staphylococcus aureus in powdered infant formula (PIF) based on multiplex loop-mediated isothermal amplification (mLAMP) combined with lateral flow dipstick (LFD). Three different species-specific target genes, siiA of Salmonella spp., internal transcribed space (ITS) of Cronobacter spp., and nuc of Staph. aureus, were applied in the mLAMP with biotin-, digoxin-, and Texas Red-modified forward inner primers and fluorescein isothiocyanate (FITC)-modified backward inner primers. After mLAMP, a large number of modified amplicons were detected with LFD; one end of the amplicon was conjugated to the anti-FITC antibody on gold nanoparticles and the other end to streptavidin (anti-digoxin or anti-Texas Red antibody) on test lines. Visual inspection of the device relies on the presence of a red band formed by accumulation of sandwich composites. The detection limits of this mLAMP-LFD assay for Salmonella spp., Cronobacter spp., and Staph. aureus in PIF without enrichment were 4.2, 2.6, and 3.4 cfu/g, respectively. The whole method can be completed in less than 1 h. Thus, mLAMP-LFD is a rapid and efficient method for simultaneously detecting Salmonella spp., Cronobacter spp., and Staph. aureus in PIF.
Copyright © 2020 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  food-borne pathogen; lateral flow dipstick; multiplex loop-mediated isothermal amplification; powdered infant formula

Year:  2020        PMID: 32113770     DOI: 10.3168/jds.2019-17538

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  4 in total

Review 1.  Antibody- and nucleic acid-based lateral flow immunoassay for Listeria monocytogenes detection.

Authors:  Matheus Bernardes Torres Fogaça; Arun K Bhunia; Leonardo Lopes-Luz; Eduardo Pimenta Ribeiro Pontes de Almeida; José Daniel Gonçalves Vieira; Samira Bührer-Sékula
Journal:  Anal Bioanal Chem       Date:  2021-05-26       Impact factor: 4.142

Review 2.  Progress in the Application of Nanoparticles and Graphene as Drug Carriers and on the Diagnosis of Brain Infections.

Authors:  Mahmood Barani; Mahwash Mukhtar; Abbas Rahdar; Ghasem Sargazi; Anna Thysiadou; George Z Kyzas
Journal:  Molecules       Date:  2021-01-02       Impact factor: 4.411

3.  Optimizing Effective Parameters to Enhance the Sensitivity of Vertical Flow Assay for Detection of Escherichia coli.

Authors:  Manpreet Kaur; Evgeni Eltzov
Journal:  Biosensors (Basel)       Date:  2022-01-25

4.  Simultaneous Detection of Five Foodborne Pathogens Using a Mini Automatic Nucleic Acid Extractor Combined with Recombinase Polymerase Amplification and Lateral Flow Immunoassay.

Authors:  Bei Jin; Biao Ma; Jiali Li; Yi Hong; Mingzhou Zhang
Journal:  Microorganisms       Date:  2022-07-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.