Literature DB >> 32109891

The silicon-photomultiplier: fundamentals and applications of a modern solid-state photon detector.

Stefan Gundacker1, Arjan Heering2.   

Abstract

The silicon-photomultiplier (SiPM) is an established device of choice for a variety of applications, e.g. in time of flight positron emission tomography (TOF-PET), lifetime fluorescence spectroscopy, distance measurements in LIDAR applications, astrophysics, quantum-cryptography and related applications as well as in high energy physics (HEP). To fully utilize the exceptional performances of the SiPM, in particular its sensitivity down to single photon detection, the dynamic range and its intrinsically fast timing properties, a qualitative description and understanding of the main SiPM parameters and properties is necessary. These analyses consider the structure and the electrical model of a single photon avalanche diode (SPAD) and the integration in an array of SPADs, i.e. the SiPM. The discussion will include the front-end readout and the comparison between analog-SiPMs, where the array of SPADs is connected in parallel, and the digital SiPM, where each SPAD is read out and digitized by its own electronic channel. For several applications a further complete phenomenological view on SiPMs is necessary, defining several SiPM intrinsic parameters, i.e. gain fluctuation, afterpulsing, excess noise, dark count rate, prompt and delayed optical crosstalk, single photon time resolution (SPTR), photon detection effieciency (PDE) etc. These qualities of SiPMs influence directly and indirectly the time and energy resolution, for example in PET and HEP. This complete overview of all parameters allows one to draw solid conclusions on how best performances can be achieved for the various needs of the different applications. Creative Commons Attribution license.

Entities:  

Keywords:  Geiger mode avalanche; HEP; SPAD; SiPM; Solid state photon detector; TOF-PET; Timing

Year:  2020        PMID: 32109891     DOI: 10.1088/1361-6560/ab7b2d

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

Review 1.  Photon counting detectors and their applications ranging from particle physics experiments to environmental radiation monitoring and medical imaging.

Authors:  Ryosuke Ota
Journal:  Radiol Phys Technol       Date:  2021-03-19

2.  Study of optical reflectors for a 100ps coincidence time resolution TOF-PET detector design.

Authors:  Andrea Gonzalez-Montoro; Shirin Pourashraf; Min Sun Lee; Joshua W Cates; Craig S Levin
Journal:  Biomed Phys Eng Express       Date:  2021-09-15

3.  Investigation of Electronic Signal Processing Chains for a Prototype TOF-PET System With 100-ps Coincidence Time Resolution.

Authors:  Shirin Pourashraf; Andrea Gonzalez-Montoro; Min Sun Lee; Joshua W Cates; Jun Yeon Won; Jae Sung Lee; Craig S Levin
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-11-02

Review 4.  Advances in Preclinical PET.

Authors:  Stephen S Adler; Jurgen Seidel; Peter L Choyke
Journal:  Semin Nucl Med       Date:  2022-03-18       Impact factor: 4.802

5.  High resolution detectors for whole-body PET scanners by using dual-ended readout.

Authors:  Zheng Liu; Ming Niu; Zhonghua Kuang; Ning Ren; San Wu; Longhan Cong; Xiaohui Wang; Ziru Sang; Crispin Williams; Yongfeng Yang
Journal:  EJNMMI Phys       Date:  2022-04-21

Review 6.  Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review.

Authors:  Haewook Park; Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-07-16

7.  Radiation Damage in Polyethylene Naphthalate Thin-Film Scintillators.

Authors:  Marcello Campajola; Francesco Di Capua; Pierluigi Casolaro; Ettore Sarnelli; Alberto Aloisio
Journal:  Materials (Basel)       Date:  2022-09-21       Impact factor: 3.748

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.