Literature DB >> 32107654

Fully-automated production of [68Ga]Ga-PentixaFor on the module Modular Lab-PharmTracer.

Sarah Spreckelmeyer1, Oliver Schulze2, Winfried Brenner2.   

Abstract

BACKGROUND: PentixaFor is a promising radiopharmaceutical for positron emission tomography in the detection of different tumor entities and other diseases. Until now, the synthesis of [68Ga]Ga-PentixaFor was reported for the automated synthesis module from Scintomics® only. Our aim was to evaluate the automated synthesis of this radiopharmaceutical on a different module in order to make it available for a broader community.
RESULTS: The synthesis of [68Ga]Ga-PentixaFor with different amounts of PentixaFor (50 μg, 30 μg and 20 μg) on the Modular Lab PharmTracer (MLPT) from Eckert & Ziegler with the already established synthesis template for [68Ga]Ga-DOTATOC yielded best results with 50 μg PentixaFor for clinical multi-dose application. All different quality control parameters tested (e.g. sterility, stability and radiochemical purity) were in accordance with the European Pharmacopoeia.
CONCLUSIONS: [68Ga]Ga-PentixaFor was successfully synthesized fully-automated on the synthesis module Modular Lab PharmTracer and can be used for multi-dose application in clinical settings.

Entities:  

Keywords:  Automated production; CXCR4; Imaging; PentixaFor

Year:  2020        PMID: 32107654     DOI: 10.1186/s41181-020-0091-2

Source DB:  PubMed          Journal:  EJNMMI Radiopharm Chem        ISSN: 2365-421X


  2 in total

Review 1.  Good practices for 68Ga radiopharmaceutical production.

Authors:  Bryce J B Nelson; Jan D Andersson; Frank Wuest; Sarah Spreckelmeyer
Journal:  EJNMMI Radiopharm Chem       Date:  2022-10-22

Review 2.  Cold Kit Labeling: The Future of 68Ga Radiopharmaceuticals?

Authors:  Nicolas Lepareur
Journal:  Front Med (Lausanne)       Date:  2022-02-10
  2 in total