Literature DB >> 32096412

Sensitivity-Enhanced Fourier Transform Mid-Infrared Spectroscopy Using a Supercontinuum Laser Source.

Ivan Zorin1, Jakob Kilgus1, Kristina Duswald1, Bernhard Lendl2, Bettina Heise1, Markus Brandstetter1.   

Abstract

Fourier transform infrared (FT-IR) spectrometers have been the dominant technology in the field of mid-infrared (mid-IR) spectroscopy for decades. Supercontinuum laser sources operating in the mid-IR spectral region now offer the potential to enrich the field of FT-IR spectroscopy due to their distinctive properties, such as high-brightness, broadband spectral coverage and enhanced stability. In our contribution, we introduce this advanced light source as a replacement for conventional thermal emitters. Furthermore, an approach to efficient coupling of pulsed mid-IR supercontinuum sources to FT-IR spectrometers is proposed and considered in detail. The experimental part is devoted to pulse-to-pulse energy fluctuations of the applied supercontinuum laser, performance of the system, as well as the noise and long-term stability. Comparative measurements performed with a conventional FT-IR instrument equipped with a thermal emitter illustrate that similar noise levels can be achieved with the supercontinuum-based system. The analytical performance of the supercontinuum-based FT-IR spectrometer was tested for a concentration series of aqueous formaldehyde solutions in a liquid flow cell (500 µm path length) and compared with the conventional FT-IR (130 µm path length). The results show a four-times-enhanced detection limit due to the extended path length enabled by the high brightness of the laser. In conclusion, FT-IR spectrometers equipped with novel broadband mid-IR supercontinuum lasers could outperform traditional systems providing superior performance, e.g., interaction path lengths formerly unattainable, while maintaining low noise levels known from highly stable thermal emitters.

Entities:  

Keywords:  FT-IR; Fourier transform infrared spectroscopy; Mid-infrared spectroscopy; mid-IR; supercontinuum laser source

Year:  2020        PMID: 32096412     DOI: 10.1177/0003702819893364

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  1 in total

1.  Towards Real-Time In-Situ Mid-Infrared Spectroscopic Ellipsometry in Polymer Processing.

Authors:  Alexander Ebner; Robert Zimmerleiter; Kurt Hingerl; Markus Brandstetter
Journal:  Polymers (Basel)       Date:  2021-12-21       Impact factor: 4.329

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.