Literature DB >> 32092721

Effect of central retainer shape and abduction angle during preparation of teeth on dentin and cement layer stress distributions in endocrown-restored mandibular molars.

Junxin Zhu1, Dongmei Wang2, Qiguo Rong3, Jun Qian2, Xiaoyan Wang1.   

Abstract

To study the effect of central retainer shape and abduction angle during tooth preparation on stress distribution in endocrown-restored molars via finite element (FE) analysis, we constructed five FE models with different central retainer shapes and abduction angles. Under an oblique load, the distributions of maximum tensile stress in cervical dentin around the endocrown and on the cement layer, as well as maximum shear stress on the cement layer, were more balanced in the FE model in which the central retainer shape was generated based on the anatomical form of the pulp chamber. Moreover, there were no differences in stress distributions among FE models with different abduction angles. Therefore, the shape of the central retainer should be designed on the basis of the anatomical form of the pulp chamber; abduction angle during tooth preparation does not influence the repair effect of endocrown-restored mandibular molars.

Entities:  

Keywords:  Cement interface; Endocrown; Finite element analysis; Stress distribution

Year:  2020        PMID: 32092721     DOI: 10.4012/dmj.2019-050

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  4 in total

1.  [Effect of occlusal thickness design on the fracture resistance of endocrowns restored with lithium disilicate ceramic and zirconia].

Authors:  Zhen-Xiang Lin; Zai-Xing Pan; Qi-Qing Ye; Zhi-Qiang Zheng; Jie Lin
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-12-01

2.  [Effects of the resin base and retention depth on fracture resistance of molars restored with nano-ceramic endocrowns].

Authors:  Z Li; Y X Xu; X D Bao; X Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

3.  Effect of Restorative Material on Mechanical Response of Provisional Endocrowns: A 3D-FEA Study.

Authors:  João Paulo Mendes Tribst; Alexandre Luiz Souto Borges; Laís Regiane Silva-Concílio; Marco Antonio Bottino; Mutlu Özcan
Journal:  Materials (Basel)       Date:  2021-01-31       Impact factor: 3.748

4.  Fracture resistance, failure mode and stress concentration in a modified endocrown design.

Authors:  Wiam El Ghoul; Mutlu Özcan; Joao Paulo Mendes Tribst; Ziad Salameh
Journal:  Biomater Investig Dent       Date:  2020-08-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.