Literature DB >> 32092708

Feasibility and limitations of quantitative SPECT for 223Ra.

Johan Gustafsson1, Emilia Rodeño, Pablo Mínguez.   

Abstract

The aim of this paper is to investigate the feasibility and limitations of activity-concentration estimation for 223Ra using SPECT. Phantom measurements are performed using spheres (volumes 5.5 mL to 26.4 mL, concentrations 1.6 kBq mL-1 to 4.5 kBq mL-1). Furthermore, SPECT projections are simulated using the SIMIND Monte Carlo program for two geometries, one similar to the physical phantom and the other being an anthropomorphic phantom with added lesions (volumes 34 mL to 100 mL, concentrations 0.5 kBq mL-1 to 4 kBq mL-1). Medium-energy and high-energy collimators, 60 projections with 55 s per projection and a 20% energy window at 82 keV are employed. For the Monte Carlo simulated images, Poisson-distributed noise is added in ten noise realizations. Reconstruction is performed (OS-EM, 40 iterations, 6 subsets) employing compensation for attenuation, scatter, and collimator-detector response. The estimated concentrations in the anthropomorphic phantom are also corrected using recovery coefficients. Errors for the largest sphere in the physical phantom range from -25% to -34% for the medium-energy collimator and larger deviations for smaller spheres. Corresponding results for the high-energy collimator are -15% to -31%. The corresponding Monte Carlo simulations show standard deviations of a few percentage points. For the anthropomorphic phantom, before application of recovery coefficients the bias ranges from -16% to -46% (medium-energy collimator) and -10% to -28% (high-energy collimator), with standard deviations of 2% to 14% and 1% to 16%. After the application of recovery coefficients, the biases range from -3% to -35% (medium energy collimator) and from 0% to -18%. The errors decrease with increasing concentrations. Activity-concentration estimation of 223Ra with SPECT is feasible, but problems with repeatability need to be further studied.

Year:  2020        PMID: 32092708     DOI: 10.1088/1361-6560/ab7971

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Estimation of the lower limits for feasible Ra-223 SPECT imaging: a Monte Carlo simulation study.

Authors:  Akihiko Takahashi; Hibiki Ueno; Shingo Baba; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2021

2.  Practical considerations for quantitative clinical SPECT/CT imaging of alpha particle emitting radioisotopes.

Authors:  Nadia Benabdallah; William Scheve; Nicholas Dunn; Delynn Silvestros; Paul Schelker; Diane Abou; Uday Jammalamadaka; Richard Laforest; Zekun Li; Jonathan Liu; David H Ballard; Nichole M Maughan; Hiram Gay; Brian C Baumann; Robert F Hobbs; Buck Rogers; Amir Iravani; Abhinav K Jha; Farrokh Dehdashti; Daniel L J Thorek
Journal:  Theranostics       Date:  2021-09-27       Impact factor: 11.556