Literature DB >> 32089428

Flash glucose monitoring (FGM): A clinical review on glycaemic outcomes and impact on quality of life.

Eshen Ang1, Zong Xuan Lee2, Sacha Moore2, Melanie Nana2.   

Abstract

Flash glucose monitoring (FGM) is widely accepted as an alternative means to conventional finger prick test for measuring glucose level in individuals with diabetes mellitus. In this clinical review, we endeavour to draw all available clinical evidence on the usage and efficacy of FGM from research trials and observational studies in real-world settings. We aim to explore its clinical efficacy and impact on quality of life (QoL) in the diabetic population. In terms of clinical outcomes, use of FGM is associated with a significant reduction in glycated haemoglobin A1c (HbA1c) level, notably in patients with suboptimal glycaemic control prior to commencement of FGM and reduction in time spent in hypoglycaemia. FGM demonstrated non-inferiority in device accuracy when compared to other well-established CGMs available in the market. Patients have reported improved QoL and treatment satisfaction measured by validated objective scores after consistent use of FGM. This results in a positive impact on patient psychosocial wellbeing and ultimately enhances patient compliance and optimisation of glycaemic control. Evaluation of QoL and patient reported outcome measures (PROMs) will require a standardised approach to allow comparability of the results and evidence. Crown
Copyright © 2020. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Flash glucose monitoring; FreeStyle Libre; Patient-reported outcome measure; Quality of life; Type 1 diabetes mellitus

Year:  2020        PMID: 32089428     DOI: 10.1016/j.jdiacomp.2020.107559

Source DB:  PubMed          Journal:  J Diabetes Complications        ISSN: 1056-8727            Impact factor:   2.852


  5 in total

Review 1.  Continuous glucose monitoring systems for monitoring cystic fibrosis-related diabetes.

Authors:  Aileen Toner; Anna McCloy; Paula Dyce; Dilip Nazareth; Freddy Frost
Journal:  Cochrane Database Syst Rev       Date:  2021-11-29

2.  Hemoglobin A1c modifies the association between triglyceride and time in hypoglycemia determined by flash glucose monitoring in adults with type 1 diabetes: implications for individualized therapy and decision-making.

Authors:  Yiwen Liu; Jie Yu; Chifa Ma; Shuli He; Fan Ping; Huabing Zhang; Wei Li; Lingling Xu; Xinhua Xiao; Yuxiu Li
Journal:  Ann Transl Med       Date:  2021-04

Review 3.  Expert Panel Recommendations for Use of Standardized Glucose Reporting System Based on Standardized Glucometrics Plus Visual Ambulatory Glucose Profile (AGP) Data in Clinical Practice.

Authors:  Selcuk Dagdelen; Oguzhan Deyneli; Nevin Dinccag; Hasan Ilkova; Zeynep Osar Siva; Ilhan Yetkin; Temel Yilmaz
Journal:  Front Endocrinol (Lausanne)       Date:  2022-01-24       Impact factor: 5.555

4.  Commencement of flash glucose monitoring is associated with a decreased rate of depressive disorders among persons with diabetes (FLARE-NL7).

Authors:  Julia J Bakker; Annel Lameijer; Jose L Flores Guerrero; Henk J G Bilo; Peter R van Dijk
Journal:  BMJ Open Diabetes Res Care       Date:  2022-06

Review 5.  Flash Glucose Monitoring and Patient Satisfaction: A Meta-Review of Systematic Reviews.

Authors:  Ana Díez-Fernández; María Dolores Rodríguez-Huerta; Rubén Mirón-González; José Alberto Laredo-Aguilera; Noelia María Martín-Espinosa
Journal:  Int J Environ Res Public Health       Date:  2021-03-18       Impact factor: 3.390

  5 in total