Literature DB >> 32085945

Treating Very Long Coronary Artery Lesions in the Contemporary Drug-Eluting-Stent Era: Single Long 48 mm Stent Versus Two Overlapping Stents Showed Comparable Clinical Outcomes.

Hui Wen Sim1, Elizabeth H Thong1, Poay Huan Loh1, Chi-Hang Lee2, Mark Y Chan2, Adrian F Low2, Edgar L Tay2, Koo Hui Chan1, Huay Cheem Tan2, Joshua P Loh3.   

Abstract

BACKGROUND/
PURPOSE: Percutaneous coronary intervention (PCI) of diffuse coronary artery disease (CAD) is associated with higher adverse clinical events. This study aimed to compare the clinical outcomes of patients treated with single long 48 mm contemporary drug eluting stents (SL-DES) versus two overlapping contemporary drug eluting stents (OL-DES) for very-long CAD. METHODS/MATERIALS: We analyzed the clinical outcome of 117 patients with SL-DES and 101 patients with OL-DES who underwent PCI between 1st July 2013 to 31st December 2016. The primary endpoint was target lesion failure (TLF) at two years, defined as a composite of cardiac mortality, target vessel myocardial infarction and target lesion revascularization.
RESULTS: Mean age was 60.8 ± 10.5 years for SL-DES group and 60.5 ± 11.9 years in the OL-DES group. SL-DES has longer mean lesion length as compared to OL-DES (43.1 ± 3.7 mm vs. 41.83 ± 2.3 mm p = 0.003). There was no difference in TLF at two years between SL-DES and OL-DES (5.3% vs. 6.4%, adjusted odds ratio 1.43, 95% CI 0.50-4.11). There was one case of probable ST in each group. Contrast volume usage was lower for SL-DES than OL-DES in patients who underwent single vessel PCI.
CONCLUSIONS: Treatment of very-long CAD showed comparable TLF at two years for SL-DES versus OL-DES. Our results suggest that both strategies are reasonable treatment options for patients with diffuse CAD.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Contemporary drug eluting stent; Diffuse coronary artery disease; Everolimus eluting stents; Overlapping stents; Percutaneous coronary intervention

Mesh:

Substances:

Year:  2020        PMID: 32085945     DOI: 10.1016/j.carrev.2020.02.005

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  1 in total

1.  Safety and efficacy of Everolimus-Eluting bioabsorbable Polymer-Coated stent in patients with long coronary lesions: The EVOLVE 48 study.

Authors:  Dimitrios Karmpaliotis; Robert Stoler; Simon Walsh; Seif El-Jack; Srinivasa Potluri; Jeffrey Moses; Keith Oldroyd; Adrian Banning; Mark Webster; Azfar Zaman; Willis Wu; Mudassar Ahmed; Paul Underwood; Dominic Allocco
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-29       Impact factor: 2.585

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.