Literature DB >> 32082713

The effect of transcatheter aortic valve implantation on Tp-e interval, Tp-e/QT and Tp-e/QTc ratios, and Tp-e dispersion in patients with severe aortic stenosis.

Zülkif Tanrıverdi1, Tuğçe Çöllüoğlu2, Barış Ünal3, Hüseyin Dursun2, Dayimi Kaya2.   

Abstract

BACKGROUND: In this study, we aimed to investigate the effect of transcatheter aortic valve implantation using two types of bioprosthetic valves on novel ventricular repolarization markers including Tp-e, Tp-e/QT and Tpe/QTc ratios, and Tp-ed.
METHODS: A total of 61 patients (17 males, 44 females; mean age 78.6±6.5 years; range 55 to 89 years) who underwent transcatheter aortic valve implantation with either a Medtronic CoreValve (n=40) or an Edwards SAPIEN XT valve (n=21) were retrospectively analyzed. The electrocardiographic parameters and left ventricular mass index were calculated prior to the procedure, on postoperative Day 1, and at three months after the procedure.
RESULTS: The Tp-e interval, Tp-e/QT and Tp-e/QTc ratios, Tp-ed, and left ventricular mass index significantly reduced at three months of the procedure, compared to baseline values (p<0.01, for all). Similar findings were observed for QT, QTc, and QT dispersion (p<0.01, for all). These changes were independent from the types of bioprosthetic valves used. Before the procedure, the left ventricular mass index was positively correlated with the Tp-e (r=0.350, p=0.007), Tp-e/QT (r=0.314, p=0.015) and Tp-e/QTc ratios (r=0.285, p=0.029). In the multivariate analysis, Tp-e interval was found to be independently associated with the left ventricular mass index (b=0.350, p=0.007).
CONCLUSION: In the present study, the Tp-e interval, Tp-e/QT and Tp-e/QTc ratios, Tp-ed, and left ventricular mass index significantly reduced at three months after transcatheter aortic valve implantation indicating reverse left ventricular remodeling. The effects of two types of bioprosthetic valves on ventricular repolarization markers and left ventricular mass index were similar.
Copyright © 2018, Turkish Society of Cardiovascular Surgery.

Entities:  

Keywords:  Aortic valve stenosis; electrocardiography; heart valve prosthesis; ventricular repolarization markers

Year:  2018        PMID: 32082713      PMCID: PMC7018127          DOI: 10.5606/tgkdc.dergisi.2018.14819

Source DB:  PubMed          Journal:  Turk Gogus Kalp Damar Cerrahisi Derg        ISSN: 1301-5680            Impact factor:   0.332


  31 in total

1.  The terminal part of the QT interval (T peak to T end): a predictor of mortality after acute myocardial infarction.

Authors:  Gunnar Erikssen; Knut Liestøl; Lars Gullestad; Kristina H Haugaa; Bjørn Bendz; Jan P Amlie
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-04       Impact factor: 1.468

2.  The meaning of the Tp-Te interval and its diagnostic value.

Authors:  Jan A Kors; Henk J Ritsema van Eck; Gerard van Herpen
Journal:  J Electrocardiol       Date:  2008 Nov-Dec       Impact factor: 1.438

3.  Early regression of left ventricular mass associated with diastolic improvement after transcatheter aortic valve implantation.

Authors:  Enrico Vizzardi; Antonio D'Aloia; Claudia Fiorina; Silvia Bugatti; Giovanni Parrinello; Marco De Carlo; Cristina Giannini; Vitantonio Di Bello; Anna Sonia Petronio; Salvatore Curello; Federica Ettori; Livio Dei Cas
Journal:  J Am Soc Echocardiogr       Date:  2012-07-18       Impact factor: 5.251

4.  Tpeak-Tend and Tpeak-Tend dispersion as risk factors for ventricular tachycardia/ventricular fibrillation in patients with the Brugada syndrome.

Authors:  Jesus Castro Hevia; Charles Antzelevitch; Francisco Tornés Bárzaga; Margarita Dorantes Sánchez; Francisco Dorticós Balea; Roberto Zayas Molina; Miguel A Quiñones Pérez; Yanela Fayad Rodríguez
Journal:  J Am Coll Cardiol       Date:  2006-04-17       Impact factor: 24.094

5.  Increased QT dispersion and other repolarization abnormalities as a possible cause of electrical instability in isolated aortic stenosis.

Authors:  V Ducceschi; B Sarubbi; A D'Andrea; B Liccardo; N Briglia; A Carozza; J Marmo; L Santangelo; A Iacono; M Cotrufo
Journal:  Int J Cardiol       Date:  1998-03-13       Impact factor: 4.164

Review 6.  Ventricular arrhythmias in adult aortic stenosis: prevalence, mechanisms, and clinical relevance.

Authors:  A Sorgato; P Faggiano; G P Aurigemma; C Rusconi; W H Gaasch
Journal:  Chest       Date:  1998-02       Impact factor: 9.410

7.  Association between Tp-e/QT ratio and prognosis in patients undergoing primary percutaneous coronary intervention for ST-segment elevation myocardial infarction.

Authors:  Xiangmei Zhao; Zhouliang Xie; Yingjie Chu; Lei Yang; Wenkai Xu; Xianzhi Yang; Xiaoyu Liu; Lixiao Tian
Journal:  Clin Cardiol       Date:  2012-06-27       Impact factor: 2.882

8.  Transcatheter aortic valve implantation reduces sympathetic activity and normalizes arterial spontaneous baroreflex in patients with aortic stenosis.

Authors:  Nicolas Dumonteil; Angelica Vaccaro; Fabien Despas; Marc Labrunee; Bertrand Marcheix; Elisabeth Lambert; Murray Esler; Didier Carrie; Jean-Michel Senard; Michel Galinier; Atul Pathak
Journal:  JACC Cardiovasc Interv       Date:  2013-10-16       Impact factor: 11.195

9.  Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance study.

Authors:  Timothy A Fairbairn; Christopher D Steadman; Adam N Mather; Manish Motwani; Daniel J Blackman; Sven Plein; Gerry P McCann; John P Greenwood
Journal:  Heart       Date:  2013-06-07       Impact factor: 5.994

10.  Transcatheter aortic valve replacement in elderly patients.

Authors:  Dimytri Siqueira; Alexandre Abizaid; Magaly Arrais; J Eduardo Sousa
Journal:  J Geriatr Cardiol       Date:  2012-06       Impact factor: 3.327

View more
  1 in total

1.  The relationship between myocardial bridge and frontal QRS-T angle.

Authors:  Mustafa Begenc Tascanov; Zulkif Tanriverdi; Fatih Gungoren; Gulsen Genc Tapar; Asuman Bicer
Journal:  J Arrhythm       Date:  2022-09-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.