Phillip Zhe Sun1,2,3. 1. Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA. 2. Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA. 3. Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA.
Abstract
PURPOSE: pH-weighted amide proton transfer (APT) MRI is promising to serve as a new surrogate metabolic imaging biomarker for refined ischemic tissue demarcation. APT MRI with pulse-RF irradiation (pulse-APT) is an alternative to the routine continuous wave (CW-) APT MRI that overcomes the RF duty cycle limit. Our study aimed to generalize the recently developed pH-specific magnetization transfer and relaxation-normalized APT (MRAPT) analysis to pulse-APT MRI in acute stroke imaging. METHODS: Multiparametric MRI, including CW- and pulse-APT MRI scans, were performed following middle cerebral artery occlusion in rats. We calculated pH-sensitive MTRasym and pH-specific MRAPT contrast between the ipsilateral diffusion lesion and contralateral normal area. RESULTS: An inversion pulse of 10 to 15 ms maximizes the pH-sensitive MRI contrast for pulse-APT MRI. The contrast-to-noise ratio of pH-specific MRAPT effect between the contralateral normal area and ischemic lesion from both methods are comparable (3.25 ± 0.65 vs. 3.59 ± 0.40, P > .05). pH determined from both methods were in good agreement, with their difference within 0.1. CONCLUSIONS: Pulse-APT MRI provides highly pH-specific mapping for acute stroke imaging.
PURPOSE: pH-weighted amide proton transfer (APT) MRI is promising to serve as a new surrogate metabolic imaging biomarker for refined ischemic tissue demarcation. APT MRI with pulse-RF irradiation (pulse-APT) is an alternative to the routine continuous wave (CW-) APT MRI that overcomes the RF duty cycle limit. Our study aimed to generalize the recently developed pH-specific magnetization transfer and relaxation-normalized APT (MRAPT) analysis to pulse-APT MRI in acute stroke imaging. METHODS: Multiparametric MRI, including CW- and pulse-APT MRI scans, were performed following middle cerebral artery occlusion in rats. We calculated pH-sensitive MTRasym and pH-specific MRAPT contrast between the ipsilateral diffusion lesion and contralateral normal area. RESULTS: An inversion pulse of 10 to 15 ms maximizes the pH-sensitive MRI contrast for pulse-APT MRI. The contrast-to-noise ratio of pH-specific MRAPT effect between the contralateral normal area and ischemic lesion from both methods are comparable (3.25 ± 0.65 vs. 3.59 ± 0.40, P > .05). pH determined from both methods were in good agreement, with their difference within 0.1. CONCLUSIONS: Pulse-APT MRI provides highly pH-specific mapping for acute stroke imaging.