Literature DB >> 32075315

Detection of Salmonella Enterica in Egg Yolk by PCR on a Microfluidic Disc Device Using Immunomagnetic Beads.

Izumi Kubo1, Mitsutoshi Kajiya1, Narumi Aramaki1, Shunsuke Furutani2,3.   

Abstract

Salmonella enterica is a pathogenic bacterium that causes foodborne illness. One of the vehicle foods of S. enterica are chicken eggs. Efficient collection of the bacterium is necessary to detect it specifically. We developed a method to detect S. enterica by PCR on a microfluidic disc device using a fluorescent probe. Salmonella enterica cells were isolated in the microchambers on the device, followed by thermal lysis and PCR targeting with the invA gene, a gene specific to S. enterica, were observed by measurement of the fluorescent signal that resulted from gene amplification. However, the developed method was unable to discriminate viable cells from dead cells. Consequently, in this study, magnetic beads modified with anti-Salmonella antibody were utilized to detect viable Salmonella cells from egg yolk prior to PCR on the device. While using the antibody-modified beads, egg yolk components, which inhibit PCR, were removed. The collected cells were subsequently detected by PCR of the invA gene on a microfluidic disc device. This method enabled the detection of viable cells without the inhibition of PCR by any egg component. S. enterica was detected at 5.0×104 cells mL-1 or at a higher concentration of egg yolk within 6 h including the sampling time.

Entities:  

Keywords:  PCR; Salmonella enterica; egg yolk; immunomagnetic beads; invA

Year:  2020        PMID: 32075315     DOI: 10.3390/s20041060

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  3 in total

1.  Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects.

Authors:  Jinsoo Park; Yonghyun Lee; Youjin Hwang; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2020-09-14       Impact factor: 3.576

Review 2.  Recent advancements in microfluidic chip biosensor detection of foodborne pathogenic bacteria: a review.

Authors:  Fang Mi; Cunming Hu; Ying Wang; Li Wang; Fei Peng; PengFei Geng; Ming Guan
Journal:  Anal Bioanal Chem       Date:  2022-01-21       Impact factor: 4.478

3.  Microfluidics for the rapid detection of Escherichia coli O157:H7 using antibody-coated microspheres.

Authors:  Bo Song; Jiayuan Yu; Yan Sun; Qiao Wang; Shengnan Xu; Yichen Jia; Shuying Lin; Yueying Zhang; Chen Wang; Yingbo Zhang; Xiaojie Zhang
Journal:  Bioengineered       Date:  2021-12       Impact factor: 3.269

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.