Karolyn M Hopfensperger1, Quentin Adams2, Yusung Kim2, Xiaodong Wu3, Weiyu Xu3, Kaustubh Patwardhan2, Bounnak Thammavong4, Joseph Caster2, Ryan T Flynn2. 1. Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center for the Engineering Arts and Sciences, Iowa City, IA, 52242, USA. 2. Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, IA, 52242, USA. 3. Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center for the Engineering Arts and Sciences, Iowa City, IA, 52242, USA. 4. Bounnak Thammavong Artworks, 33060 Dawn Drive, Kingston, IL, 60145, USA.
Abstract
PURPOSE: To assess the capability of an intracavitary 169 Yb-based helical multishield rotating shield brachytherapy (RSBT) delivery system to treat cervical cancer. The proposed RSBT delivery system contains a pair of 1.25 mm thick platinum partial shields with 45° and 180° emission angles, which travel in a helical pattern within the applicator. METHODS: A helically threaded tandem applicator with a 45° tandem curvature containing a helically threaded catheter was designed. A 0.6 mm diameter 169 Yb source with a length of 10.5 mm was simulated. A 37-patient treatment planning study, based on Monte Carlo dose calculations using MCNP5, was conducted with high-risk clinical target volumes (HR-CTVs) of 41.2-192.8 cm3 (average ± standard deviation of 79.9 ± 35.8 cm3 ). All patients were assumed to receive 25 fractions of 1.8 Gy of external beam radiation therapy (EBRT) before receiving 5 fractions of high-dose-rate brachytherapy (HDR-BT). For each patient, 192 Ir-based intracavitary (IC) HDR-BT, 192 Ir-based intracavitary/interstitial (IC/IS) HDR-BT using a hybrid applicator with eight IS needles, and 169 Yb-based RSBT plans were generated. RESULTS: For the IC, IC/IS, and RSBT treatment plans, 38%, 84%, and 86% of the plans, respectively, met the planning goal of an HR-CTV D90 (minimum dose to hottest 90%) of 85 GyEQD2 (α/β = 10 Gy). Median (25th percentile, 75th percentile) treatment times for IC, IC/IS, and RSBT were 11.71 (6.62, 15.40) min, 68.00 (45.02, 80.02) min, and 25.30 (13.87, 35.39) min, respectively. 192 Ir activities ranging from 159.1-370 GBq (4.3-10 Ci) and 169 Yb activities ranging from 429.2-999 GBq (11.6-27 Ci) were used, which correspond to the same clinical ranges of dose rates at 1 cm off-source-axis in water. Extra needle insertion and planning time beyond that needed for intracavitary-only approaches was accounted for in the IC/IS treatment time calculations. CONCLUSION: 169 Yb-based RSBT for cervical cancer met the HR-CTV D90 goal of 85 Gy in a greater percentage of the patients considered than IC/IS (86% vs 84%, respectively) and can reduce overall treatment time relative to IC/IS. 169 Yb-based RSBT could be used to replace IC/IS in instances where IC/IS treatment is not available, especially in instances when HR-CTV volumes are ≥30 cm3 .
PURPOSE: To assess the capability of an intracavitary 169 Yb-based helical multishield rotating shield brachytherapy (RSBT) delivery system to treat cervical cancer. The proposed RSBT delivery system contains a pair of 1.25 mm thick platinum partial shields with 45° and 180° emission angles, which travel in a helical pattern within the applicator. METHODS: A helically threaded tandem applicator with a 45° tandem curvature containing a helically threaded catheter was designed. A 0.6 mm diameter 169 Yb source with a length of 10.5 mm was simulated. A 37-patient treatment planning study, based on Monte Carlo dose calculations using MCNP5, was conducted with high-risk clinical target volumes (HR-CTVs) of 41.2-192.8 cm3 (average ± standard deviation of 79.9 ± 35.8 cm3 ). All patients were assumed to receive 25 fractions of 1.8 Gy of external beam radiation therapy (EBRT) before receiving 5 fractions of high-dose-rate brachytherapy (HDR-BT). For each patient, 192 Ir-based intracavitary (IC) HDR-BT, 192 Ir-based intracavitary/interstitial (IC/IS) HDR-BT using a hybrid applicator with eight IS needles, and 169 Yb-based RSBT plans were generated. RESULTS: For the IC, IC/IS, and RSBT treatment plans, 38%, 84%, and 86% of the plans, respectively, met the planning goal of an HR-CTV D90 (minimum dose to hottest 90%) of 85 GyEQD2 (α/β = 10 Gy). Median (25th percentile, 75th percentile) treatment times for IC, IC/IS, and RSBT were 11.71 (6.62, 15.40) min, 68.00 (45.02, 80.02) min, and 25.30 (13.87, 35.39) min, respectively. 192 Ir activities ranging from 159.1-370 GBq (4.3-10 Ci) and 169 Yb activities ranging from 429.2-999 GBq (11.6-27 Ci) were used, which correspond to the same clinical ranges of dose rates at 1 cm off-source-axis in water. Extra needle insertion and planning time beyond that needed for intracavitary-only approaches was accounted for in the IC/IS treatment time calculations. CONCLUSION: 169 Yb-based RSBT for cervical cancer met the HR-CTV D90 goal of 85 Gy in a greater percentage of the patients considered than IC/IS (86% vs 84%, respectively) and can reduce overall treatment time relative to IC/IS. 169 Yb-based RSBT could be used to replace IC/IS in instances where IC/IS treatment is not available, especially in instances when HR-CTV volumes are ≥30 cm3 .
Authors: Christian Kirisits; Stefan Lang; Johannes Dimopoulos; Daniel Berger; Dietmar Georg; Richard Pötter Journal: Int J Radiat Oncol Biol Phys Date: 2006-06-01 Impact factor: 7.038
Authors: Lucas C Mendez; Pencilla Lang; Chirag Patel; David D'Souza; Adam Gladwish; Laura D'Alimonte; Amandeep Taggar; Elizabeth Barnes; Lisa Barbera; Eric Leung Journal: Brachytherapy Date: 2018-10-10 Impact factor: 2.362
Authors: Dietmar Georg; Johannes Hopfgartner; Joanna Gòra; Peter Kuess; Gabriele Kragl; Daniel Berger; Neamat Hegazy; Gregor Goldner; Petra Georg Journal: Int J Radiat Oncol Biol Phys Date: 2014-03-01 Impact factor: 7.038
Authors: Habib Safigholi; Dae Yup Han; Shahram Mashouf; Abraam Soliman; Ali S Meigooni; Amir Owrangi; William Y Song Journal: Med Phys Date: 2017-10-23 Impact factor: 4.071