Literature DB >> 32069280

Evaluation of a novel microfluidic immuno-magnetic agglutination assay method for detection of dengue virus NS1 antigen.

Izaskun Alejo-Cancho1, Jessica Navero-Castillejos2, Aida Peiró-Mestres2, Rosa Albarracín1, Josep Barrachina1, Alexander Navarro1, Verónica Gonzalo1, Víctor Pastor1, José Muñoz2,3, Miguel J Martínez1,2.   

Abstract

BACKGROUND: Dengue virus (DENV) is the most important arbovirus worldwide, causing infections in endemic countries and returning travellers from these areas. Rapid diagnostic tests are needed to improve patient management and monitor local transmission. The detection of DENV non-structural protein 1 (NS1) is a useful tool for the diagnosis, but the currently available methods can be time consuming or lack sensitivity. The objective of our study was to evaluate a new rapid and semi-quantitative microfluidic DENV NS1 immuno-magnetic agglutination assay based on aggregation of magnetic nanoparticles detected by an electronic reader (Virotrack Dengue Acute and Blubox, Blusense diagnostics, Copenhagen, Denmark). METHODOLOGY/PRINCIPAL
FINDINGS: A panel of 135 serum samples from travelers returning from dengue endemic countries was analyzed (74 DENV positive samples including the four DENV serotypes, 26 Zika virus positive samples, 25 chikungunya virus positive samples, 5 malaria positive samples and 5 negative samples). Samples were tested by three different antigen detection methods: SD Dengue NS1 Ag ELISA, SD BIOLINE Dengue Duo and ViroTrack Dengue Acute. The sensitivity observed for SD Dengue NS1 Ag ELISA, ViroTrack Dengue Acute and SD BIOLINE Dengue Duo was 97.2%, 91.1% and 68.1%, respectively. All methods showed high specificity (98.4% for ViroTrack Dengue Acute and 100% for both SD Dengue NS1 Ag ELISA and SD BIOLINE Dengue Duo). SD Dengue NS1 Ag ELISA and ViroTrack Dengue Acute only failed to detect samples positive for DENV-2.
CONCLUSIONS/SIGNIFICANCE: ViroTrack Dengue Acute is a sensitive and specific assay for DENV NS1 detection. It provides faster results than the ELISA method and a better performance than the rapid immunochromatographic tests. ViroTrack Dengue Acute could represent a valuable tool for rapid diagnosis of DENV infections in returning travellers from endemic countries.

Entities:  

Year:  2020        PMID: 32069280     DOI: 10.1371/journal.pntd.0008082

Source DB:  PubMed          Journal:  PLoS Negl Trop Dis        ISSN: 1935-2727


  2 in total

1.  Performance of a New Microfluidic Dengue NS1 Immuno-magnetic Agglutination Assay for the Rapid Diagnosis of Dengue Infection in Adults.

Authors:  Ekkarat Wongsawat; Yupin Suputtamongkol; Susan Assanasaen; Saowaluk Silpasakorn; Panisadee Avirutnan; Chunya Puttikhunt; Nasikarn Angkasekwinai; Eakkawit Yamasmith; Tanapan Prommool; Kanigar Niwattayakul
Journal:  Am J Trop Med Hyg       Date:  2021-07-19       Impact factor: 3.707

2.  Diagnostic Performance of a Magnetic Field-Enhanced Agglutination Readout in Detecting Either Viral Genomes or Host Antibodies in Arbovirus Infection.

Authors:  Fanny Leon; Elena Pinchon; Nevzat Temurok; François Morvan; Jean-Jacques Vasseur; Martine Clot; Vincent Foulongne; Jean-François Cantaloube; Philippe Vande Perre; Jean-Pierre Molès; Aurélien Daynès; Chantal Fournier-Wirth
Journal:  Microorganisms       Date:  2021-03-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.