Abstract

Objective: Equivalent threshold sound pressure levels (ETSPLs) were determined for RadioEar DD65v2 audiometric headphones.Design: The pure-tone hearing threshold levels were measured for 11 audiometric frequencies between 0.125 and 8 kHz, according to the conditions specified in ISO 389-9. ETSPLs are provided for an ear simulator according to IEC 60318-1, complemented by a comprehensive uncertainty budget.Study sample: The study was based on 25 otologically normal test subjects.
Results: ETSPL values are provided with expanded measurement uncertainty. The data are compared for left/right ears as well as male/female test subjects.Conclusions: The results of both studies may be used to update ISO 389-8, the RETSPL standard for circumaural audiometric headphones.

Entities:  

Keywords:  Audiometry; ETSPL; RadioEar DD65v2; reference hearing threshold

Mesh:

Year:  2020        PMID: 32069129     DOI: 10.1080/14992027.2020.1727034

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117