Literature DB >> 32069083

Iodine Parameters in Triple-Bolus Dual-Energy CT Correlate With Perfusion CT Biomarkers of Angiogenesis in Renal Cell Carcinoma.

Dinesh Manoharan1, Arjunlokesh Netaji1, Chandan J Das1, Sanjay Sharma1.   

Abstract

OBJECTIVE. The purpose of this study is to determine the degree of the relationship between perfusion CT (PCT) parameters and iodine concentration metrics derived from triple-bolus dual-energy CT (DECT) and to compare the radiation dose delivered. SUBJECTS AND METHODS. This single-center prospective study was conducted from October 2015 to September 2017. Twenty-three consenting adults (15 men and eight women; mean [± SD] age, 56 ± 13 years [range, 25-78 years]) with renal cell carcinomas underwent consecutive PCT and triple-bolus DECT examinations. Triple-bolus DECT consisted of synchronous corticomedullary, nephrographic, and delayed phase scans acquired using a dual-source DECT scanner. Two readers independently analyzed blood flow, blood volume, and permeability, as measured by PCT, and iodine density and iodine ratio, as measured by triple-bolus DECT. Size-specific dose estimates were calculated for both groups. RESULTS. Interreader agreement was good for permeability (intraclass correlation coefficient [ICC] =.812) and blood flow (ICC = 0.849) and excellent for blood volume (ICC = 0.956), iodine density (ICC = 0.961), and iodine ratio (ICC = 0.956). Very strong positive correlations were found between blood volume and iodine density (p < 0.001) and between blood volume and iodine ratio (p < 0.001). Strong positive correlations were found between blood flow and iodine density (p < 0.001) and between blood flow and iodine ratio (p < 0.001). The correlations between permeability and iodine density (p = 0.01) and between permeability and iodine ratio (p = 0.02) were moderate. The mean size-specific dose estimate of triple-bolus DECT was approximately 15 times lower than that of PCT (p < 0.001). CONCLUSION. Quantitative iodine metrics derived from triple-bolus DECT showed significant correlation with CT parameters in renal cell carcinoma, with a significantly lower radiation dose.

Entities:  

Keywords:  MDCT; iodine; perfusion imaging; radiation exposure; renal cell carcinoma

Mesh:

Substances:

Year:  2020        PMID: 32069083     DOI: 10.2214/AJR.19.21969

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  1 in total

1.  Effect of spectral CT on tumor microvascular angiogenesis in renal cell carcinoma.

Authors:  Bei Zhang; Qiong Wu; Xiang Qiu; Xiaobo Ding; Jin Wang; Jing Li; Pengfei Sun; Xiaohan Hu
Journal:  BMC Cancer       Date:  2021-07-30       Impact factor: 4.430

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.