Background: Bone-conduction hearing implants are standard of care devices.Aims/ Objectives: Evaluation of a new active magnetic bone-conduction hearing implant: Cochlear Osia™ system.Material and methods: This device uses a transcutaneous connection between an external sound-processor and an osseointegrated implant that generates vibrations using a piezoelectricity-based internal bone-conduction system. Nine patients with conductive-hearing loss were implanted. Surgical efficacy, hearing performance and quality-of-life were evaluated. Hearing performance in quiet and in noise was compared with unaided hearing and hearing with the Baha 5 Power® Sound Processor on a softband. Results: Surgery and healing were uneventful. Statistically significant improvements in audibility, speech-understanding, speech-recognition and quality-of-sound in noise and quiet were found for the Osia™ compared to preoperative unaided hearing and aided hearing with the Baha 5 Power® Sound Processor on a softband. The active vibration system provided improvement at low and high frequencies. At 6 months postoperatively, all patients continue to use the device.Conclusions and significance: The Osia™ is safe and effective, improving speech-recognition in quiet and in noise, at low and high frequencies, thus delivering better quality-of-hearing than passive devices.
Background: Bone-conduction hearing implants are standard of care devices.Aims/ Objectives: Evaluation of a new active magnetic bone-conduction hearing implant: Cochlear Osia™ system.Material and methods: This device uses a transcutaneous connection between an external sound-processor and an osseointegrated implant that generates vibrations using a piezoelectricity-based internal bone-conduction system. Nine patients with conductive-hearing loss were implanted. Surgical efficacy, hearing performance and quality-of-life were evaluated. Hearing performance in quiet and in noise was compared with unaided hearing and hearing with the Baha 5 Power® Sound Processor on a softband. Results: Surgery and healing were uneventful. Statistically significant improvements in audibility, speech-understanding, speech-recognition and quality-of-sound in noise and quiet were found for the Osia™ compared to preoperative unaided hearing and aided hearing with the Baha 5 Power® Sound Processor on a softband. The active vibration system provided improvement at low and high frequencies. At 6 months postoperatively, all patients continue to use the device.Conclusions and significance: The Osia™ is safe and effective, improving speech-recognition in quiet and in noise, at low and high frequencies, thus delivering better quality-of-hearing than passive devices.
Entities:
Keywords:
Active bone-conduction hearing-implant; Baha; Bone anchored hearing aid; hearing improvement in high frequencies; quality-of-hearing
Authors: Marcos Antonio de Souza; Santiago Luis Vallejos Riart; Stephanie Rugeri de Souza; Rubens de Brito; Ricardo Ferreira Bento Journal: Int Arch Otorhinolaryngol Date: 2022-02-04
Authors: Guy Fierens; Charlotte Borgers; Tristan Putzeys; Joris Walraevens; Astrid Van Wieringen; Nicolas Verhaert Journal: Biomed Res Int Date: 2022-04-02 Impact factor: 3.411
Authors: Katarzyna B Cywka; Piotr H Skarzynski; Bartlomiej Krol; Stavros Hatzopoulos; Henryk Skarzynski Journal: Eur Arch Otorhinolaryngol Date: 2022-02-19 Impact factor: 3.236
Authors: Robert Briggs; Catherine S Birman; Nicholas Baulderstone; Aaran T Lewis; Iris H Y Ng; Anna Östblom; Alex Rousset; Sylvia Tari; Michael C F Tong; Robert Cowan Journal: Otol Neurotol Date: 2022-08-01 Impact factor: 2.619