Literature DB >> 32068449

Clinical performance of the Osia™ system, a new active osseointegrated implant system. Results from a prospective clinical investigation.

Marcos Goycoolea1,2, Gloria Ribalta1, Francisco Tocornal1, Raquel Levy1, Pilar Alarcón1, Martin Bryman3, Byanka Cagnacci4, Catherine Catenacci2, Valeria Oyanguren4, Ignacia Vilches1, Verónica Briones1,2, Raimundo García2.   

Abstract

Background: Bone-conduction hearing implants are standard of care devices.Aims/
Objectives: Evaluation of a new active magnetic bone-conduction hearing implant: Cochlear Osia™ system.Material and methods: This device uses a transcutaneous connection between an external sound-processor and an osseointegrated implant that generates vibrations using a piezoelectricity-based internal bone-conduction system. Nine patients with conductive-hearing loss were implanted. Surgical efficacy, hearing performance and quality-of-life were evaluated. Hearing performance in quiet and in noise was compared with unaided hearing and hearing with the Baha 5 Power® Sound Processor on a softband.
Results: Surgery and healing were uneventful. Statistically significant improvements in audibility, speech-understanding, speech-recognition and quality-of-sound in noise and quiet were found for the Osia™ compared to preoperative unaided hearing and aided hearing with the Baha 5 Power® Sound Processor on a softband. The active vibration system provided improvement at low and high frequencies. At 6 months postoperatively, all patients continue to use the device.Conclusions and significance: The Osia™ is safe and effective, improving speech-recognition in quiet and in noise, at low and high frequencies, thus delivering better quality-of-hearing than passive devices.

Entities:  

Keywords:  Active bone-conduction hearing-implant; Baha; Bone anchored hearing aid; hearing improvement in high frequencies; quality-of-hearing

Mesh:

Year:  2020        PMID: 32068449     DOI: 10.1080/00016489.2019.1691744

Source DB:  PubMed          Journal:  Acta Otolaryngol        ISSN: 0001-6489            Impact factor:   1.494


  9 in total

1.  Complications of Transcutaneous Protheses - A Systematic Review of Publications Over the Past 10 Years.

Authors:  Marcos Antonio de Souza; Santiago Luis Vallejos Riart; Stephanie Rugeri de Souza; Rubens de Brito; Ricardo Ferreira Bento
Journal:  Int Arch Otorhinolaryngol       Date:  2022-02-04

2.  The Impact of Location and Device Coupling on the Performance of the Osia System Actuator.

Authors:  Guy Fierens; Charlotte Borgers; Tristan Putzeys; Joris Walraevens; Astrid Van Wieringen; Nicolas Verhaert
Journal:  Biomed Res Int       Date:  2022-04-02       Impact factor: 3.411

3.  Evaluation of the Bonebridge BCI 602 active bone conductive implant in adults: efficacy and stability of audiological, surgical, and functional outcomes.

Authors:  Katarzyna B Cywka; Piotr H Skarzynski; Bartlomiej Krol; Stavros Hatzopoulos; Henryk Skarzynski
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-02-19       Impact factor: 3.236

4.  Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®.

Authors:  Ann-Kathrin Rauch; Thomas Wesarg; Antje Aschendorff; Iva Speck; Susan Arndt
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-11-18       Impact factor: 3.236

5.  Clinical Performance, Safety, and Patient-Reported Outcomes of an Active Osseointegrated Steady-State Implant System.

Authors:  Robert Briggs; Catherine S Birman; Nicholas Baulderstone; Aaran T Lewis; Iris H Y Ng; Anna Östblom; Alex Rousset; Sylvia Tari; Michael C F Tong; Robert Cowan
Journal:  Otol Neurotol       Date:  2022-08-01       Impact factor: 2.619

6.  Pediatric morphometric study to guide the optimized implantation of the Osia® 2 implant system.

Authors:  Balint Posta; Adam Perenyi; Linda Szabo; Roland Nagy; Gabor Katona; Zsuzsanna Csakanyi; Laszlo Rovo; Zsofia Bere
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-03-16       Impact factor: 3.236

7.  Toward Optimal Care for Children With Congenital Unilateral Aural Atresia.

Authors:  Filip Asp; Robert J Stokroos; Martijn J H Agterberg
Journal:  Front Neurol       Date:  2021-07-08       Impact factor: 4.003

8.  Influence of Compression Thresholds and Maximum Power Output on Speech Understanding with Bone-Anchored Hearing Systems.

Authors:  Tom Gawliczek; Wilhelm Wimmer; Marco Caversaccio; Martin Kompis
Journal:  Biomed Res Int       Date:  2021-10-22       Impact factor: 3.411

9.  Active transcutaneous bone-anchored hearing implant: how I do it.

Authors:  S Arndt; A K Rauch; I Speck
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-06-21       Impact factor: 2.503