Literature DB >> 32057789

Clinical outcomes of patients undergoing a cardiac implantable electronic device implantation following a recent non-device-related infection.

H-C Chen1, Y-L Chen1, W-C Lee1, T-H Tsai1, K-L Pan2, Y-S Lin2, M-C Chen3.   

Abstract

BACKGROUND: Clinical outcomes of patients undergoing a cardiac implantable electronic device (CIED) implantation following a recent non-device related infection are unknown. AIM: To evaluate the clinical outcomes of patients with recent infection before CIED implantation.
METHODS: Consecutive patients (N = 1237) were classified as patients with recent infection (N = 72) and without recent infection (N = 1165). A recent infection was established by reviewing medical records, including symptoms and clinical manifestations, diagnosis of systemic inflammatory response syndrome, and quick Sequential Organ Failure Assessment (qSOFA) score. Multiple stepwise logistic regression analysis was used to identify independent predictors of in-hospital all-cause mortality.
FINDINGS: During nearly three years of follow-up, 17 patients had CIED infection (1.4%), and the incidence of CIED infection did not significantly differ between patients with and without recent infection according to symptoms and clinical manifestations (2.8% vs 1.3%, respectively; not significant). However, patients with recent infection had a significantly higher in-hospital mortality rate compared to those without recent infection (22.2% vs 0.9%, respectively; P < 0.05). In multivariate analysis, predictors of in-hospital mortality were recent infection before CIED implantation (odds ratio: 20.3; 95% confidence interval: 8.4-49.3; P < 0.001) and end-stage renal disease (4.3; 1.4-12.8; P = 0.009).
CONCLUSION: A CIED implantation is feasible in patients with recent infection if the patient is afebrile and has received an adequate duration of antibiotic therapy. Participants in shared decision-making before implant should be advised that recent infection increases in-hospital mortality risk, especially in patients with a qSOFA score of ≥2.
Copyright © 2020 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Cardiac device infection; Cardiac implantable electronic device; Mortality; Recent non-device-related infection

Mesh:

Substances:

Year:  2020        PMID: 32057789     DOI: 10.1016/j.jhin.2020.02.003

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  1 in total

1.  Evolution of Procedure Indication and Cardiovascular Risk in Transvenous Lead Extraction.

Authors:  Daniel Hofer; Michelle C Bebié; Noah Kuster; Jan Steffel; Alexander Breitenstein
Journal:  J Clin Med       Date:  2022-06-22       Impact factor: 4.964

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.