Literature DB >> 32054328

Objective cyclodeviation measurement in normal subjects by means of Cyclocheck® application.

Justyna Simiera1, Agata Joanna Ordon1, Piotr Loba1.   

Abstract

PURPOSE: To evaluate the range of cyclodeviation in normal individuals by means of Cyclocheck® application recently designed by the authors and freely available at www.cyclocheck.com.
METHODS: Healthy subjects with normal muscle balance, best-corrected visual acuity of ⩾0.8, and stereopsis on Randot charts of ⩽100 s of arc were included in the study. Two separate digital fundus photographs were taken of each eye of every patient. The disk-foveal angle was calculated using the Cyclocheck® application. The average result of the disk-foveal angle measurements were considered for data analysis.
RESULTS: A total of 131 patients met inclusion criteria for the study population. The mean value of the disk-foveal angle in the whole study group (both right and left eye) was 6.39° ± 2.72° with 5.26° ± 2.56° (range from -0.4° to 12.55°) in the right eye and 7.52° ± 2.39° (range from 1.25° to 12.76°) in the left eye. The mean value of the disk-foveal angle of the left eye was greater by 2.26° than that of the right eye.
CONCLUSION: Cyclocheck® software allows easy assessment of cyclodeviation. Normal individuals present with a positive value of the disk-foveal angle with a certain spread of the results. The analysis of obtained measurements revealed a significant asymmetry between both eyes with the left eye being more excyclodeviated in an otherwise orthotropic population, which remains a subject for further investigations.

Entities:  

Keywords:  Cyclodeviation; disk-foveal angle; ocular torsion

Mesh:

Year:  2020        PMID: 32054328     DOI: 10.1177/1120672120905312

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Development and Preliminary Validation of a Virtual Reality Approach for Measurement of Torsional Strabismus.

Authors:  Megha Bindiganavale; David Buickians; Scott R Lambert; Zachary M Bodnar; Heather E Moss
Journal:  J Neuroophthalmol       Date:  2021-11-11       Impact factor: 4.415

2.  Automated measurement of the disc-fovea angle based on DeepLabv3.

Authors:  Bo Zheng; Yifan Shen; Yuxin Luo; Xinwen Fang; Shaojun Zhu; Jie Zhang; Maonian Wu; Ling Jin; Weihua Yang; Chenghu Wang
Journal:  Front Neurol       Date:  2022-07-27       Impact factor: 4.086