Literature DB >> 32054014

A Facile Fabrication of a Potentiometric Arrayed Glucose Biosensor Based on Nafion-GOx/GO/AZO.

Jung-Chuan Chou1, Si-Hong Lin1, Tsu-Yang Lai1, Po-Yu Kuo1, Chih-Hsien Lai1, Yu-Hsun Nien2, Tzu-Yu Su2.   

Abstract

In this study, the potentiometric arrayed glucose biosensors, which were based on zinc oxide (ZnO) or aluminum-doped zinc oxide (AZO) sensing membranes, were fabricated by using screen-printing technology and a sputtering system, and graphene oxide (GO) and Nafion-glucose oxidase (GOx) were used to modify sensing membranes by using the drop-coating method. Next, the material properties were characterized by using a Raman spectrometer, a field-emission scanning electron microscope (FE-SEM), and a scanning probe microscope (SPM). The sensing characteristics of the glucose biosensors were measured by using the voltage-time (V-T) measurement system. Finally, electrochemical impedance spectroscopy (EIS) was conducted to analyze their charge transfer abilities. The results indicated that the average sensitivity of the glucose biosensor based on Nafion-GOx/GO/AZO was apparently higher than that of the glucose biosensor based on Nafion-GOx/GO/ZnO. In addition, the glucose biosensor based on Nafion-GOx/GO/AZO exhibited an excellent average sensitivity of 15.44 mV/mM and linearity of 0.997 over a narrow range of glucose concentration range, a response time of 26 s, a limit of detection (LOD) of 1.89 mM, and good reproducibility. In terms of the reversibility and stability, the hysteresis voltages (VH) were 3.96 mV and 2.42 mV. Additionally, the glucose biosensor also showed good anti-inference ability and reproducibility. According to these results, it is demonstrated that AZO is a promising material, which could be used to develop a reliable, simple, and low-cost potentiometric glucose biosensor.

Entities:  

Keywords:  aluminum-doped zinc oxide (AZO); arrayed electrodes; glucose; graphene oxide (GO); potentiometric biosensor; zinc oxide (ZnO)

Year:  2020        PMID: 32054014     DOI: 10.3390/s20040964

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  3 in total

1.  Recent Advances in Potentiometric Biosensing.

Authors:  Nicole L Walker; Anastasiya B Roshkolaeva; Andrei I Chapoval; Jeffrey E Dick
Journal:  Curr Opin Electrochem       Date:  2021-03-17

2.  The fast nucleation/growth of Co3O4 nanowires on cotton silk: the facile development of a potentiometric uric acid biosensor.

Authors:  Munirah D Albaqami; Shymaa S Medany; Ayman Nafady; Mazhar Hussain Ibupoto; Magnus Willander; Aneela Tahira; Umair Aftab; Brigitte Vigolo; Zafar Hussain Ibupoto
Journal:  RSC Adv       Date:  2022-06-22       Impact factor: 4.036

3.  The Characteristics Analysis of a Microfluid-Based EGFET Biosensor with On-Chip Sensing Film for Lactic Acid Detection.

Authors:  Po-Yu Kuo; Chun-Hung Chang; Wei-Hao Lai; Tai-Hui Wang
Journal:  Sensors (Basel)       Date:  2022-08-07       Impact factor: 3.847

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.