Nebulization of Vancomycin Provides Higher Lung Tissue Concentrations than Intravenous Administration in Ventilated Female Piglets with Healthy Lungs.

Cristiane Luchesi de Mello Morais1, Jorge Willian Leandro Nascimento, Aline Corrêa Ribeiro, Luis Ignacio Cortinez, Maria José Carvalho Carmona, Débora Rothstein Ramos Maia, Antoine Monsel, José Otavio Costa Auler, Jean-Jacques Rouby, Denise Aya Otsuki.   

Abstract

BACKGROUND: Intravenous vancomycin is used to treat ventilator-associated pneumonia caused by methicillin-resistant Staphylococcus aureus, but achieves high rates of failure. Vancomycin nebulization may be efficient to provide high vancomycin lung tissue concentrations. The aim of this study was to compare lung tissue and serum concentrations of vancomycin administered intravenously and by aerosol in mechanically ventilated and anesthetized healthy piglets.
METHODS: Twelve female piglets received a single intravenous dose of vancomycin (15 mg/kg) and were killed 1 (n = 6) or 12 h (n = 6) after the end of administration. Twelve piglets received a single nebulized dose of vancomycin (37.5 mg/kg) and were killed 1 (n = 6) or 12 h (n = 6) after the end of the aerosol administration. In each group, vancomycin lung tissue concentrations were assessed on postmortem lung specimens using high-performance liquid chromatography. Blood samples were collected for serum vancomycin concentration measurement 30 min and 1, 2, 4, 6, 8, and 12 h after the end of vancomycin administration. Pharmacokinetics was analyzed by nonlinear mixed effect modeling.
RESULTS: One hour after vancomycin administration, lung tissue concentrations in the aerosol group were 13 times the concentrations in the intravenous group (median and interquartile range: 161 [71, 301] μg/g versus 12 [4, 42] μg/g; P < 0.0001). Twelve hours after vancomycin administration, lung tissue concentrations in the aerosol group were 63 (23, 119) μg/g and 0 (0, 19) μg/g in the intravenous group (P < 0.0001). A two-compartment weight-scaled allometric model with first-order absorption and elimination best fit serum pharmacokinetics after both routes of administration. Area under the time-concentration curve from 0 to 12 h was lower in the aerosol group in comparison to the intravenous group (56 [8, 70] mg · h · l vs. 121 [103, 149] mg · h · l, P = 0.002). Using a population model, vancomycin bioavailability was 13% (95% CI, 6 to 69; coefficient of variation = 85%) and absorption rate was slow (absorption half life = 0.3 h).
CONCLUSIONS: Administration of vancomycin by nebulization resulted in higher lung tissue concentrations than the intravenous route.

Entities:  

Year:  2020        PMID: 32053565     DOI: 10.1097/ALN.0000000000003171

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  2 in total

Review 1.  Inhaled antibiotics during mechanical ventilation-why it will work.

Authors:  Maxime Desgrouas; Stephan Ehrmann
Journal:  Ann Transl Med       Date:  2021-04

2.  A bench-to-bedside study about trigger asynchronies induced by the introduction of external gas into the non-invasive mechanical ventilation circuit.

Authors:  Cristina Lalmolda; Pablo Flórez; Carles Grimau; Roberto Larrosa; Marta Corral; Javier Sayas; Manel Luján
Journal:  Sci Rep       Date:  2021-12-10       Impact factor: 4.379