Literature DB >> 32052200

The benefits of carbon black, gold and magnetic nanomaterials for point-of-harvest electrochemical quantification of domoic acid.

Joost L D Nelis1, Davide Migliorelli2, Safiye Jafari2, Silvia Generelli2, Javier Lou-Franco3, J Pablo Salvador4,5, M Pilar Marco4,5, Cuong Cao3, Christopher T Elliott3, Katrina Campbell3.   

Abstract

Gold nanostars (GNST), gold nanospheres (GNP) and carbon black (CB) are chosen as alternative nanomaterials to modify carbon screen-printed electrodes (c-SPEs). The resulting three kinds of modified c-SPEs (GNP-SPE, CB-SPE and GNSP-SPE) were electrochemically and microscopically characterized and compared with standardized c-SPEs after pretreatment with phosphate buffer by pre-anodization (pre-SPE). The results show outstanding electrochemical performance of the carbon black-modified SPEs which show low transient current, low capacitance and good porosity. A competitive chronoamperometric immunoassay for the shellfish toxin domoic acid (DA) is described. The performances of the CB-SPE, GNP-SPE and pre-SPE were compared. Hapten-functionalized magnetic beads were used to avoid individual c-SPE functionalization with antibody while enhancing the signal by creating optimum surface proximity for electron transfer reactions. This comparison shows that the CB-SPE biosensor operated best at a potential near - 50 mV (vs. Ag/AgCl) and enables DA to be determined with a detection limit that is tenfold lower compared to pre-SPE (4 vs. 0.4 ng mL-1). These results show very good agreement with HPLC data when analysing contaminated scallops, and the LOD is 0.7 mg DA kg-1 of shellfish. Graphical abstractSchematic representation of the magnetic bead-based immunoassay for the quantification of domoic acid (DA) in shellfish with nanomaterial-modified screen-printed electrodes. CB, carbon black; GNP, gold nanospheres; GNST, gold nanostars; MB, magnetic beads; DA-mAb, anti-DA monoclonal mouse antibody; HRP-pAb, horseradish conjugated polyclonal goat anti-mouse antibody; DA-BSA, bovine serum albumin conjugated DA; HQ, hydroquinone; BQ, benzoquinone.

Entities:  

Keywords:  Amperometry; Biosensor; Food analyses; Marine toxin; Material characterization; Point of care; Point of site; Shellfish; Toxin

Year:  2020        PMID: 32052200     DOI: 10.1007/s00604-020-4150-x

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  2 in total

Review 1.  Electrochemical Biosensors in Food Safety: Challenges and Perspectives.

Authors:  Antonella Curulli
Journal:  Molecules       Date:  2021-05-15       Impact factor: 4.411

Review 2.  Current Trends and Challenges for Rapid SMART Diagnostics at Point-of-Site Testing for Marine Toxins.

Authors:  Michael Dillon; Maja A Zaczek-Moczydlowska; Christine Edwards; Andrew D Turner; Peter I Miller; Heather Moore; April McKinney; Linda Lawton; Katrina Campbell
Journal:  Sensors (Basel)       Date:  2021-04-03       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.