Literature DB >> 32052065

A quantum dot-based lateral flow immunoassay for the rapid, quantitative, and sensitive detection of specific IgE for mite allergens in sera from patients with allergic rhinitis.

Zheng-Yan Liang1, Yu-Qin Deng1, Ze-Zhang Tao2,3.   

Abstract

The prevalence of allergic rhinitis (AR) is increasing worldwide. However, the current systems used to measure levels of immunoglobulin E (IgE) in sera are associated with several disadvantages that limit their further application. Consequently, there is a need to develop novel highly sensitive strategies that can rapidly detect IgE in a quantitative manner. The development of such systems will significantly enhance our ability to diagnose, treat, and even prevent AR. Herein, we describe our experience of using quantum dot-based lateral flow immunoassay (QD-LFIA), combined with a portable fluorescence immunoassay chip detector (PFICD), to detect serum-specific IgE against Dermatophagoides pteronyssinus (Der-p) and Dermatophagoides farinae (Der-f), two common mite allergens in China. Our data showed that our system could detect serum-specific levels of IgE against Der-p and Der-f as low as 0.093 IU/mL and 0.087 IU/mL, respectively. We also established a standard curve to determine serum-specific IgE concentrations that correlated well with the clinical BioIC microfluidics system. The sensitivity of our assay was 96.7% for Der-p and 95.5% for Der-f, while the specificity was 87.2% for Der-p and 85.3% for Der-f. Collectively, our results demonstrate that QD-LFIA is a reliable system that could be applied to detect serum-specific IgE in accordance with clinical demands. This QD-LFIA strategy can be applied at home, in hospitals, and in pharmacies, with reduced costs and time requirements when compared with existing techniques. In the future, this system could be developed to detect other types of allergens and in different types of samples (for example, whole blood). Graphical abstract We describe our experiment using a quantum dot-based lateral flow immunoassay combined with a portable fluorescence immunoassay chip detector for both qualitative and quantitative detection of serum-specific IgE against two common mite allergens. This strategy can be applied at home, in hospitals, and in pharmacies, with reduced costs and time requirements. In the future, this system could be developed to detect other types of allergens and in different types of samples.

Entities:  

Keywords:  Allergic rhinitis; Immunoglobulin E; Lateral flow immunoassay; Quantum dots

Year:  2020        PMID: 32052065     DOI: 10.1007/s00216-020-02422-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Knockdown of lncRNA ANRIL suppresses the production of inflammatory cytokines and mucin 5AC in nasal epithelial cells via the miR-15a-5p/JAK2 axis.

Authors:  Huo-Wang Liu; Zhong-Liang Hu; Hao Li; Qi-Feng Tan; Jing Tong; Yong-Quan Zhang
Journal:  Mol Med Rep       Date:  2020-12-16       Impact factor: 2.952

2.  Lateral Flow Immunoassay Based on Time-Resolved Fluorescence Microspheres for Rapid and Quantitative Screening CA199 in Human Serum.

Authors:  Xueshima Jiao; Tao Peng; Zhanwei Liang; Yalin Hu; Bo Meng; Yang Zhao; Jie Xie; Xiaoyun Gong; You Jiang; Xiang Fang; Xiaoping Yu; Xinhua Dai
Journal:  Int J Mol Sci       Date:  2022-09-01       Impact factor: 6.208

Review 3.  Recent Developments in Innovative Magnetic Nanoparticles-Based Immunoassays: From Improvement of Conventional Immunoassays to Diagnosis of COVID-19.

Authors:  Yeonjeong Ha; Ijung Kim
Journal:  Biochip J       Date:  2022-07-05       Impact factor: 4.229

4.  Electrochemical Immunosensor for Human IgE Using Ferrocene Self-Assembled Monolayers Modified ITO Electrode.

Authors:  Myungsang Park; Yesol Song; Ki Jun Kim; Seung Jun Oh; Jun Ki Ahn; Hun Park; Hang-Beum Shin; Seong Jung Kwon
Journal:  Biosensors (Basel)       Date:  2020-04-14

5.  Recent Trends in Nanomaterial-Based Biosensors for Point-of-Care Testing.

Authors:  Xu Wang; Feng Li; Yirong Guo
Journal:  Front Chem       Date:  2020-10-16       Impact factor: 5.221

6.  Red Zn2SiO4:Eu3+ and Mg2TiO4:Mn4+ nanophosphors for on-site rapid optical detections: Synthesis and characterization.

Authors:  Su-Hua Yang; Hao-Yu Zhang; Chih-Chia Huang; Yi-Yan Tsai; Shun-Ming Liao
Journal:  Appl Phys A Mater Sci Process       Date:  2021-07-10       Impact factor: 2.584

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.