Association between human health and indoor air pollution in the Gulf Cooperation Council (GCC) countries: a review.

Patrick Amoatey1, Hamid Omidvarborna1, Mahad Said Baawain2, Abdullah Al-Mamun1, Aynul Bari3, Warren B Kindzierski4.   

Abstract

Studies on the assessment of indoor air pollutants in terms of concentration and characterization in the Gulf Cooperation Council (GCC) countries have been recently carried out. This review assesses the health effects associated with indoor air pollution exposures in GCC, including other air pollutants (siloxanes, flame retardants, synthetic phenolic antioxidants) which were not explored in a previous study. In addition, the influence of ventilation conditions due to different indoor environments was also investigated. It was revealed that there is a lack of human health assessment studies on most indoor air pollutants in almost all GCC countries, except the United Arab Emirates, Kingdom of Saudi Arabia and Kuwait, where few attempts were made for some specific pollutants. Commonly reported plausible health effects potentially associated with indoor air pollution were related to respiratory symptoms and sick building syndrome (SBS). Many of the current health assessment studies in GCC countries were based on predictions and/or estimates of exposures rather than clinically based observational studies. Measured ventilation levels and indoor air velocities in most buildings failed to meet the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) threshold limits of 8 L/s/p and 0.18-0.25 m/s, respectively. Additionally, limited studies have investigated respiratory symptoms and SBS potentially attributable to poor ventilation in the region. It is highly recommended that future indoor air quality (IAQ) studies in GCC should focus more on epidemiologic and intervention studies.

Entities:  

Keywords:  GCC countries; health assessment; indoor air pollution; respiratory symptons; ventilation

Year:  2020        PMID: 32049656     DOI: 10.1515/reveh-2019-0065

Source DB:  PubMed          Journal:  Rev Environ Health        ISSN: 0048-7554            Impact factor:   3.458


  2 in total

1.  ADFIST: Adaptive Dynamic Fuzzy Inference System Tree Driven by Optimized Knowledge Base for Indoor Air Quality Assessment.

Authors:  Jagriti Saini; Maitreyee Dutta; Gonçalo Marques
Journal:  Sensors (Basel)       Date:  2022-01-28       Impact factor: 3.576

2.  Impact of building ventilation systems and habitual indoor incense burning on SARS-CoV-2 virus transmissions in Middle Eastern countries.

Authors:  Patrick Amoatey; Hamid Omidvarborna; Mahad Said Baawain; Abdullah Al-Mamun
Journal:  Sci Total Environ       Date:  2020-05-12       Impact factor: 7.963