Determining the effective pre-oxygenation interval in obstetric patients using high-flow nasal oxygen and standard flow rate facemask: a biased-coin up-down sequential allocation trial.

K Au1, W Shippam1, J Taylor1, A Albert2, A Chau1.   

Abstract

Using biased-coin sequential allocation, we sought to determine the effective time interval in 90% of healthy parturients to achieve a target endpoint end-tidal oxygen of ≥ 90% using standard flow rate facemask and high-flow nasal oxygen. Eighty healthy parturients were randomly assigned to standard facemask (n = 40) or high-flow nasal oxygen (n = 40) groups; half of the parturients in the high-flow nasal oxygen group also used a simple no-flow facemask to minimise air entrainment. The effective time interval for 90% of parturients to achieve the target endpoint for standard facemask was 3.6 min (95%CI 3.3-6.7 min), but could not be estimated for the high-flow nasal oxygen groups with or without an additional simple facemask, as eight minutes was insufficient to achieve the target endpoint for 55% and 92% of parturients, respectively. Furthermore, after three minutes, the target endpoint was reached by 71% in the standard facemask group vs. 0% in the high-flow nasal oxygen groups. After four minutes, the target endpoint was reached by 100% in the standard facemask, 80% in the high-flow nasal oxygen with simple facemask and 67% in the high-flow nasal oxygen groups. Beyond four minutes, there was no improvement in pre-oxygenation success using high-flow nasal oxygen. In conclusion, under the conditions of our study, the effective time interval for 90% of parturients to achieve an end-tidal oxygen ≥ 90% for standard flow rate facemask was estimated to be 3.6 min, but could not be estimated for high-flow nasal oxygen groups even after eight minutes.
© 2020 Association of Anaesthetists.

Entities:  

Keywords:  difficult airway: caesarean section; high-flow nasal oxygen; hypoxia general anaesthesia: pregnancy; management of difficult airway; pre-oxygenation

Year:  2020        PMID: 32048278     DOI: 10.1111/anae.14995

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  2 in total

1.  Effect of variable pre-oxygenation endpoints on safe apnoea time using high flow nasal oxygen for women in labour: a modelling investigation.

Authors:  Daniel Stolady; Marianna Laviola; Arani Pillai; Jonathan G Hardman
Journal:  Br J Anaesth       Date:  2021-02-03       Impact factor: 9.166

2.  Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 1. Difficult airway management encountered in an unconscious patient.

Authors:  J Adam Law; Laura V Duggan; Mathieu Asselin; Paul Baker; Edward Crosby; Andrew Downey; Orlando R Hung; Philip M Jones; François Lemay; Rudiger Noppens; Matteo Parotto; Roanne Preston; Nick Sowers; Kathryn Sparrow; Timothy P Turkstra; David T Wong; George Kovacs
Journal:  Can J Anaesth       Date:  2021-06-18       Impact factor: 5.063

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.